MAURY USCG vessel records
← All vessels

GOODWIN

GOODWIN is a 1978 towing vessel. The Coast Guard has recorded 5 inspections since 2017, most recently in October 2024, along with 26 deficiencies.

Records from 2017 to 2024. Most recent: inspection, 17 October 2024.

Built
1978
Last inspected
17 October 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1433825
Flag
UNITED STATES
Maury page id
psix-1433825

Inspections, by type

Years with a record 4 calendar years (2017–2024)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it164 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 5

17 October 2024 Annual Inspection · Drydock Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8021048
2 October 2023 Deficiency Check · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7801712
5 April 2023 Deficiency Check · Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7663479
23 August 2021 Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7295297
8 March 2017 Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6102025

Deficiency record · 26

03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 January 2025 Resolved
The master must ensure that all hatches, door, and other openings designed to be watertight or weather-tight function properly. Discovered five deck hatches with wasted knife edges and frozen dogs that will not allow a watertight seal. Repair or renew hatches. Hatches affected are: Forward void hatch, port and starboard forward hold hatches and, port and starboard aft void hatches.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 March 2026
Resolution: All hatches were replaced.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 January 2025 Resolved
The OCMI may require additional examinations of the vessel whenever he or she discovers damage or deterioration to hull plating or structural members that affect the seaworthiness or fitness for service of the vessel. These examinations may include a drydock examination including: An internal examination of any affected space of the vessel including its fuel tanks; A removal from service to assess the extent of the damage and to affect permanent repairs. The watertight bulkhead separating the forward hold and fuel oil tank has severe wastage in two sections on the port and starboard sides. Crop and renew affected sections of plating.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 October 2025
Resolution: Renewed steel plating on bulkhead.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 January 2025 Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of and least 50 psi. Fire pump unable to produce adequate pressure and flow for even one hydrant at a time. Make effective repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 October 2025
Resolution: rebuilt fire pump. Test Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 January 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Master reported that there was a problem with the starboard steering rudder that is affecting the vessel's ability to maneuver. He stated that he believes the rudder is missing. Make effective repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 October 2025
Resolution: Rudders were inspected during non-credit DD. Rudders were in good condition. After vessel was refloated, a satisfactory stearing test was conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 January 2025 Resolved
Each lifejacket must have a light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Each lifejacket must have a whistle firmly secured by a cord to the lifejacket. All lifejackets onboard were missing lights and whistles.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 October 2025
Resolution: Lifejackets were fitted with lights and whistles.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 January 2025 Resolved
An exposed hazard such as gears and rotating equipment must be protected by a cover or guard. Neither air compressor located in the engine room have guards protecting the pulley and belt assembly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2025
Resolution: Guard was installed on air compressor.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 January 2025 Resolved
Emergency lighting must be provided for all internal crew working and living areas and must provide sufficient illumination under emergency conditions to facilitate egress from each space. Emergency lighting next to the switchboard is not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2025
Resolution: Emergency lighting was replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 January 2025 Resolved
Electrical systems must function properly and minimize failures and fire and shock hazards. Found numerous dead end wires throughout the engine room. Either remove the wires or elecrically isolate wires and terminate them within an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2025
Resolution: Electrical goom was completed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 January 2025 Resolved
Each Towing vessel must be equipped with a sound signal. The vessel's horn is inoperable. Repair vessel's horn.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2025
Resolved 23 October 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 January 2025 Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard. Towing gear examinations are not being recorded. Conduct examinations of the towing gear as required in 46 CFR 140.801 and record the examinations in accordance with 46 CFR 140.820
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2025
Resolved 21 October 2025
Resolution: Towing gear log was created. Initial inspections was captured.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 January 2025 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. Navigation assessments are not being conducted. Conduct navigation assessments as required, and record the navigation assessment in accordance with 46 CFR 140.635(d).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2025
Resolved 21 October 2025
Resolution: Created log book that better meets the navigational assement requirements
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 2 January 2025 Resolved
Prior to assuming duties related to the safe operation of a towing vessel, each crewmember other than credentialed mariners holding Able Seaman or officer endorsements must receive navigation safety training. Conduct navigation safety training, and record training in accordance with 46 CFR 140.645(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2025
Resolved 21 October 2025
Resolution: Training completed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 2 January 2025 Resolved
Any towing vessel with alternating watches (shift work)or overnight accommodations must identify the duties and duty stations of each person on board during an emergency. The vessel's station bill does not identify the duties and duty stations of each person on board during an emergency. Generate a station bill in accordance with 46 CFR 140.405.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2025
Resolved 21 October 2025
Resolution: created station bill
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 October 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided:(5) high bilge levels. Vessel had no operable high bilge level alarms and no means for visible and audible at operating station. Vessel shall ensure all high level bilge alarms are operable and to the satisfaction of the attending marine inspector prior to movement. 46 CFR 143.230(a)(5)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 November 2023
Resolution: Vessel installed high level bilge alarms. However, no audible was installed at operating station. New 835 was issued to reflect audible deficiency.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 October 2023 Resolved
To stop flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion enginer or generator prime mover. The valve must be operable from a safe place outside the space where the valve is installed. Vessels port remote fuel shutoff was relocated to be operating from inside the engine room space. Vessel shall ensure valve is operable from a safe place outside of the space to the satisfaction of the attending marine inspector prior to movement. 46 CFR 143.260(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 November 2023
Resolution: Valve is now operable from outside the space. Test SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 4 October 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Supply piping for both generator turbos was replaced with flexible supply fan hose with poses an fire threat and is not in accordance with manufactures recommendations. Vessel shall replace supply piping to turbo to the satisfaction of the attending marine inspector prior to movement. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 November 2023
Resolution: Vessel installed adequate fixed supply piping to turbo intake. Inspection and test SAT.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 October 2023 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exerior of the vessel which may allow water to enter the vessel. Old bilge overboard piping leading to the outside of the hull was open and unable to be secured from elements outside of the sideshell of the vessel. Vessel shall remove piping and properly repair sideshell or cap off piping to ensure watertight integrity prior to movement. 46 CFR 144.320(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 November 2023
Resolution: Vessel capped off piping. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 4 October 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port Main Engine Racor filter was leaking fuel. Vessel shall make repairs to the satisfaction of the attending marine inspector prior to movement. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 November 2023
Resolution: Racor leak is repaired. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 October 2023 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exerior of the vessel which may allow water to enter the vessel. Escape watertight hatch from Aft Steering room does not seal properly. Vessel shall ensure watertight integrity of the hatch to the satisfaction of the attending Marine Inspector. 46 CFR 144.320(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 8 November 2023
Resolution: Hatch knife edge was cleaned. Gasket replaced and hatch is adjusted and watertight. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 October 2023 Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 for specified areas where the vessel operates. Vessel only had 3 flares and 2 within expiration. Vessel shall obtain 4 more flares in accordance with CFR. 46 CFR 141.375(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 7 November 2023
Resolution: Vessel obtained new flares. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2023 Resolved
Atleast two lifebuoys on a towing vessel greater than 26ft must be fitted with a floating electric water light approved under 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. Vessels port side floating electric water light is inoperable. Vessel shall make repairs in accordance with CFR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 7 November 2023
Resolution: ALl float lights are now operable. All SAT.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 4 October 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided:(6) Low hydraulic steering fluid levels. Vessel had no steering low fluid level alarm and no means for visible and audible at operating station. Vessel shall ensure all alarms are operable and to the satisfaction of the attending marine inspector. 46 CFR 143.230(a)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 7 November 2023
Resolution: Low steering fluid alarm is installed. All SAT.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 4 October 2023 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Alarm setpoints have not been witnessed and shall be conducted in the presence of the attending marine inspector twice every 5 years with no more than 3 years elapsing since last test. 46 CFR 143.245(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 23 July 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 October 2023 Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Bilge suctions were found to not have check valves. Vessel shall install check valves at each suction and demonstrate working condition of the installed bilge system to the satisfaction of the attending marine inspector. 46 CFR 143.275
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 24 April 2024
Resolution: Installed check valve in each bilge suction pipe
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided:(5) high bilge levels. Vessel installed new high level bilge alarms but had no audible at operating station. Vessel shall ensure all high level bilge alarms are operable and to the satisfaction of the attending marine inspector. 46 CFR 143.230(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 24 April 2024
Resolution: Installed audible alarm at operating station. MI witnessed test of alarm
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2023 Resolved
PROPULSION MACHINERY, INCLUDING MAIN ENGINES, REDUCTION GEARS, SHAFTING, BEARINGS, AND ELECTRICAL EQUIPMENT AND SYSTEMS, MUST: (1) BE MAINTAINED TO ENSURE PROPER OPERATION; (2) BE SUITABLE FOR ROUTE AND SERVICE UPON INSPECTION OF THE STARBOARD RUDDER REPAIRS, MARINE INSPECTORS IDENTIFIED WIRE ROPE WRAPPED AROUND STARBOARD TAIL SHAFT IN WAY OF THE STERN BEARING. WIRE ROPE MUST BE REMOVED. SHAFT JOURNAL AND STERN BEARING MUST BE MADE AVAILABLE FOR INSPECTION BY THE ATTENDING MARINE INSPECTOR.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 April 2023
Resolution: conducted satisfactory inspection of shaft and stern bearing.

Ownership record