Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it43471 - Convention (Subpart B), Gross Ton 27254 - Convention (Subpart B), Net Ton 81704 - Dead Weight, Metric Ton 94676 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 April 2025Resolved
SELF-CLOSING FIRE DOORS OF THE SAME FIRE INTEGRITY STANDARDS SHALL BE FITTED IN THE ENCLOSURE. PSCO OBSERVED THAT THE DOOR TO THE STEERING ROOM DID NOT CLOSE AND LATCH WHEN RELEASED.
74 SOLAS 2020 II-2/4.2.1.1
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2025
Resolved 18 April 2025
Resolution: CREW RECTIFIED DOOR BY ADJUSTING CLOSER.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 18 April 2025Resolved
ON ALL SHIPS, WITHIN THE MACHINERY SPACES, EMERGENCY ESCAPE BERTHING DEVICES SHALL BE SITUATED READY FOR USE AT EASILY VISIBLE SPACES. PSCO OBSERVED A COMPLETELY DEPLETED EEBD IN THE ENGINE ROOM (ECR).
74 SOLAS 2020 II-2/4.3.1
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2025
Resolved 18 April 2025
Resolution: CREW REPLACED EMPTY EEBD WITH SPARE.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2025Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT: THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED MULTIPLE EXPOSED ELECTRICAL SESNORS ON ALL THREE GENERATORS AND EXPOSED CABLES EXTENDING FROM THE 220V SWITCHBOARD IN ENGINE CONTROL ROOM AND ENGINE ROOM.
74 SOLAS 2020 II-1/40.1.3
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2025
Resolved 18 April 2025
Resolution: CREW CAPPED ALL EXPOSED WIRING.