MAURY USCG vessel records
← All vessels

CABO MISAKI

CABO MISAKI is a 2017 tank ship. The Coast Guard has recorded 15 inspections since 2017, most recently in May 2026, along with 3 deficiencies and 1 operational control.

Records from 2017 to 2026. Most recent: inspection, 11 May 2026.

Built
2017
Last inspected
11 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9755062
1434170
Flag
PANAMA
Maury page id
psix-1434170

Documentation record

Tonnage as PSIX records it74177 - Dead Weight, Metric Ton
89227 - Displacement, Metric Ton
42794 - Convention (Subpart B), Gross Ton
21760 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

11 May 2026 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8370820
28 January 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8303161
26 January 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8302048
21 May 2025 PSC B · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8140986
22 May 2024 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7916697
16 June 2023 PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7710001
14 June 2022 COC-TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7477324
27 March 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7419320
26 February 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7402490
13 September 2021 COC-TVE Annual · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7311154
22 August 2020 PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7039879
26 November 2019 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6862865
1 November 2019 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6843657
24 September 2018 Deficiency Check · COC-TVE Renew · Administrative Inspection · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6543181
10 April 2017 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6118636

Deficiency record · 3

14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 13 September 2021 Resolved
FOLLOWING INSTALLATION, THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF THE VESSEL SUBJECT TO THIS SUBPART MUST PROPERLY MAINTAIN THE BWMS IN ACCORDANCE WITH ALL MANUFACTURERS SPECIFICATIONS. PSCO FOUND BWMS INOPERABLE. 33 CFR 151.2025 50 AC
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2021
Resolution: Received tech report for rectification of BWMS
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 1 November 2019 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the administration. Exposed wiring discovered in vacinity of broken overfill alarm light located above port side cargo manifold. Prior to loading cargo in United States, replace overfill alarm and exposed wiring. SOLAS (2014) II-1 REG 45.5.4 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 November 2019
Resolution: BV classification society survey report #CTG0/ANC/201911120938 stating deficiency issued from Activity #6843657 has been rectified. Survey report states: New overfill alarm light was fitted to replace the broken alarm and tested satisfactory.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 24 September 2018 Resolved
74SOLAS(14) II-2/4.4.4.1.1 17ac Tankers of 20,000 gross tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance w/ the requirements of the fire safety system's code. PSCO observed ingert gas capacity control valve was not working as per design.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2018
Resolution: Class report submitted attesting to the rectification of the deficiency.

Ownership record