MAURY USCG vessel records
← All vessels

GAS UTOPIA

GAS UTOPIA is a 2017 tank ship. The Coast Guard has recorded 9 inspections since 2019, most recently in June 2026, along with 4 deficiencies and 6 operational controls.

Records from 2019 to 2026. Most recent: operational control imposed, 5 June 2026.

Built
2017
Last inspected
5 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 June 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9770531
1434899
Flag
PANAMA
Maury page id
psix-1434899

Documentation record

Tonnage as PSIX records it28672 - Dead Weight, Metric Ton
39826 - Displacement, Metric Ton
25049 - Convention (Subpart B), Gross Ton
7514 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

5 June 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8392628
15 January 2026 PSC B · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8293736
19 April 2024 Deficiency Check · PSC B · PSC A · COC-GAS Renew
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7893121
23 April 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6942851
3 April 2020 COC-GAS Renew · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6933793
22 August 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6791143
5 June 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6705011
21 March 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6646796
18 January 2019 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6609838

Deficiency record · 4

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 April 2024 Resolved
15109 - Safety Management Systems - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the objective evidence detailed in the below deficiencies, the vessel is not in compliance with relevant conventions, calling into question the adequacy and implementation of the vessel's SMS under the ISM code. In addition to the deficiencies below, the vessel's crew was observed performing maintenance on #1 cargo tank high-level alarm piping flange, which was actively leaking anhydrous ammonia, without personal protective equipment. After review of the ship's SMS, it was determined the crew was not adhering to their approved procedures. Due to hazards present on the vessel including an acute exposure to anhydrous ammonia, PSCO's suspended the inspection. In accordance with Port State Control Procedures 3.6, suspension of the exam will continue until responsible parties ensure the vessel complies with all relevant requirements. An external audit is required to determine whether the ship is operating in accordance with the ISM code. -74 SOLAS(20)IX/3.1 ISM A/10.1 -30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 April 2024
Resolution: Received audit report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 April 2024 Resolved
06199 - Cargo Operations Including Equipment - Arrangements should be made for sealing the weather decks in way of opening for cargo containment systems. During the exam USCG examiners were exposed to anhydrous ammonia. After crew investigation it was determined the cargo tank #1 high-level alarm pipping flange was leaking. -74SOLAS(20)VII/13.1 IGC Code (93) 3.1.7 -30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 21 April 2024
Resolution: Marine chemist verified that leak bad been corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 April 2024 Resolved
02108 - Structural Conditions - Intrinsically safe electrical equipment and wiring may be fitted in all gas-dangerous spaces and zones as defined in 1.3.17. PSCO observed multiple damaged electrical components in the cargo compressor room, cargo tank tops, and on independent deck cargo tanks. All wire penetrations to equipment were damaged, or had unapproved gasket sealant causing them to no longer be intrinsically safe. -74SOLAS(20)VII/13.1 IGC Code (93) Reg 10.2.1 -30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 April 2024
Resolution: All electrical equipment was repaired/replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Entry dangerous spaces
Issued 19 April 2024 Resolved
09221 - Working and Living Conditions - An airlock should only be permitted between a gas-dangerous zone on the open weather deck and a gas-free space and should consist of two steel doors substantially gastight spaced as least 1.5M but not more than 2.5M apart. PSCO observed the outer door of the airlock, leading to the gas-dangerous zone, did not have gastight integrity due to visible sunlight between the knife edge and door gasket. -74 SOLAS (20) VII/3.1 IGC Code (93) Reg 3.6 -30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 April 2024
Resolution: Crew demonstrated the door properly seals.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.