Records from 2000 to 2025. Most recent: inspection, 18 September 2025.
Documentation record
Registered dimensions (L × B × D)55.5 ft × 24.0 ft × 8.5 ft
Registered tonnagegross 90 / net 70
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderW.D.JEFFREY · FORT SMITH AR, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFORT SMITH, AR
Trade endorsementsCoastwise, Bowaters
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
70 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
18 September 2025
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8225916
26 September 2024
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8009831
25 September 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7796594
15 September 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7559065
13 May 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7450016
24 September 2020
COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7064461
23 January 2020
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6894926
19 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6503413
21 June 2018
MTSA/ISPS Verification · Deficiency Check · COI Inspection · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6485586
4 December 2012
Industry Initiated Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4496138
13 July 2000
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 212227
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 September 2023
Resolved
Vessel's propulsion shafts (Port & STBD) are missing appropriate protection to prevent accidental injury from rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2023
Resolved 3 October 2023
Resolution: Installed guards over the rotating propulsion shafts. Unit rcvd email with pictures attached.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 September 2022
Resolved
Vessel's whistle was incapable of producing an effective sound that can be heard at a distand of 0.5 nautical miles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 29 September 2022
Resolution: Company installed a new electronic horn that was considerably louder (audible for at least 0.5 nautical miles).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 September 2022
Resolved
COI listed 08 lifejackest as being required. Only 06 lifejackets of an approved type were found onboard. Vessel will need 02 additional lifejackets to meet COI requirements.
Action required: 705 - Other - as specified
Due 22 September 2022
Resolved 29 September 2022
Resolution: Company purchased additional lifejackets with lights/whistles.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 13 May 2022
Resolved
Port and Starboard generators were found to have flexible fuel line connections only containing single hose clamps.
Action required: 705 - Other - as specified
Due 20 May 2022
Resolved 19 May 2022
Resolution: Operator installed additional hose clamps on all flexible fuel line connections on both generators.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2022
Resolved
Distress signals onboard were found to be expired.
Action required: 705 - Other - as specified
Due 20 May 2022
Resolved 19 May 2022
Resolution: Operator installed new distress signals that were current and ready for use.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2022
Resolved
The vessel's name was not installed on either side of the vessel.
Action required: 705 - Other - as specified
Due 20 May 2022
Resolved 19 May 2022
Resolution: Operator installed legible markings containing the vessel's name on the port & starboard sides of the superstructure (wheelhouse)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2018
Resolved
The batteries installed in the water lights is not of an approved type in accordance with the manufacturer. Replace the battery with an approved battery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2018
Resolved 27 July 2018
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 June 2018
Resolved
The engine room air intake and engine room exhaust currently do not have means to close openings. Provide means to close the openings.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2018
Resolved 27 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 June 2018
Resolved
The B-V fire extinguisher is permanently affixed to the deck inside the engine room and the hose length is unable to reach all areas of the vessel. Remove extinguisher from brackets so extinguisher can move and reach all areas or install a longer hose.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 July 2018
Resolved 27 July 2018
Resolution: Deficiency correct on the spot. Extinguisher was moved outside the engine room and is no longer permanently attached to the vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 21 June 2018
Resolved
Captain did not have a valid medical certificate. Obtain a new medical ceritficate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2018
Resolved 27 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2018
Resolved
The bilge pump does not have a check valve installed to prevent unintended back flooding. Install a check valve in the bilge line.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2018
Resolved 27 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2018
Resolved
The bilge high level alarm is required to be both audible and visual in the pilot house. Correct the alarm so that it is also audible.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2018
Resolved 27 July 2018