← All vessels
YK NEWPORT
YK NEWPORT is a 2017 freight ship. The Coast Guard has recorded 13 inspections since 2017, most recently in February 2026, along with 3 deficiencies and 2 operational controls.
Records from 2017 to 2026. Most recent: operational control imposed, 3 February 2026.
- Built
- 2017
- Last inspected
- 3 February 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded2
Years with a record
7 calendar years (2017–2026)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it43036 - Convention (Subpart B), Gross Ton
81756 - Dead Weight, Metric Ton
94361 - Displacement, Metric Ton
27490 - Convention (Subpart B), Net Ton
81756 - Dead Weight, Metric Ton
94361 - Displacement, Metric Ton
27490 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 13
3 February 2026
Administrative Inspection · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8305312
3 February 2026
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8305890
29 January 2026
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8303656
22 August 2025
Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8209239
13 August 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8209121
6 September 2023
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7786037
25 March 2021
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7147526
8 March 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7152181
4 June 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6687679
1 February 2018
Deficiency Check · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6339129
26 September 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6264983
25 September 2017
Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6274577
12 September 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6264971
Deficiency record · 3
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 August 2025
Resolved
Where a fixed gas fire-extinguishing system is used operning which may admit air to, or allow gas to escape from, a protected space shall be capeable of being closed from outside the protected space. PSCO observed missing fire caps from channel drains due to design.
74 SOLAS (20) II-2/10.4.2
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 4 June 2019
Resolved
The International Load Line Certificate shall not be delivered to the ship until the surveyor has certified that the marks are correctly indicated on the ship's sides. The load line markings do not reflect the markings identified under the load line certificate number (18ST0017-LLC-2/2), which was endorsed on May 7, 2019.
ILLC Reg. 9
40 ac
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 25 September 2017
Resolved
0940-Following installation the master, owner, operator, agent or person in charge of the vessel subject to this part must properly maintain the BWMS in accordance with all manufacturer specifications. PSCO noted the BWTS is not properly operating in accordance with manufacturer specifications. 33 CFR 151.2025
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.