AMIS CHAMPION is a 2014 freight ship. The Coast Guard has recorded 12 inspections since 2017, most recently in March 2025, along with 8 deficiencies — 1 with no resolution recorded — and 4 operational controls.
Records from 2017 to 2025. Most recent: inspection, 18 March 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19911 - Convention (Subpart B), Net Ton 19911 - Regulatory (Subpart C or D), Net Ton 60830 - Dead Weight, Metric Ton 70851 - Displacement, Metric Ton 33937 - Regulatory (Subpart C or D), Gross Ton 33937 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
18 March 2025Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8092751
11 March 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8092092
18 January 2023Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7623094
8 December 2021PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7353572
14 October 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6561060
2 August 2018Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6498917
17 July 2018ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6470394
11 July 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6475128
30 January 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6346555
29 January 2018Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6345720
13 January 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6337367
16 April 2017Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6124559
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 18 March 2025No resolution recorded
Bulk carriers shall comply with the maintenance requirements provided in regulation II-1/3-1 and the standards for owners' inspection and maintenance of bulk carrier hatch covers, adopted by the Organization by resolution MSC.169(79). PSCO noted that the hatch maintenance requirements were not being followed. The gaskets on the quick acting cleats were frozen on numerous cargo holds.
74 Solas (20) XII/7.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 December 2021Resolved
Ships shall be provided with arrangements, equipment, and fittings of sufficent safe working load to enable the safe conduct of all mooring operations. PSCO observed 03 mooring lines wasted, with the core exposed. Lines were identified as; port spring, port quarter, starboard bow.
74 SOLAS (2) II-1/3-8.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2021
Resolved 15 December 2021
Resolution: Provided proof of new lines.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 July 2018Resolved
10111-Charts-Nautical charts and nautical publications necessary for the intended voyage shall be adequate and up to date. PSCO observed chart #3384 was outdated; last update Week 24. SOLAS 74 (a) 2014 cons. V/27 17 a
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2018
Resolution: Class report received attesting to proper update of charts.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2018Resolved
07110-Firefighting equipment and appliances-There shall be in each boiler room or at an entrance outside of the boiler room at least one portable foam applicator unit complying with the provisions of the FSS Code. A portable foam applicator shall consist of a foam nozzle/branch pipe together with a portable tank containing at least 20L of foam concentrate and at least one spare tank of foam concentrate of the same capacity. PSCO observed portable foam concentrate and spare actively leaking. SOLAS 74 (a) 2014 cons. II-2/10.5.1.2.1 FSS 4/3.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2018
Resolution: Class report submitted attesting to the replacement of one portable 20L container and the cleanup of residues. Report confirmed applicator was in good working condition, however the hose was replaced.
01108-Load Lines- Details of Load Line markings shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed STBD Load Line was not in contrasting color to the hull. ICLL Annex I/8 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018
Resolved 18 July 2018
Resolution: Class report received attesting to the proper painting of STBD load line.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 17 July 2018Resolved
99103-Other-Each transfer pipe system on board a vessel to be tested under static liquid pressure at least 1. times the maximum allowable working pressure annually. PSCO observed the vessel last tested on 30May2017. Vessel to test as per reference prior to bunkering in net U.S. port. 33CFR156
.170 c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 August 2018
Resolution: Vessel submitted documentation certifying hydrostatic testing of bunker lines completed iaw regulations.
Lifesaving › Inflatable Liferafts › Container Construction
Issued 16 April 2017Resolved
Code: 0620 Cite: 74SOLAS(09)III/20.2 Action: 40ac Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessels 6 man liferaft has exterior damage which could possibly compromise the water tight integrity and the serviceability of the raft. Vessel is scheduled for dry dock 20MAY17.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2018
Resolution: Received Servicing Report and Photos of the repaired liferaft capsule.
Electrical › Electric Generation Source (emergency) › Generator
Issued 16 April 2017Resolved
Code: 1499 Cite: 74SOLAS(09)II-I/44.2 Action: 10c A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. Vessels secondary means of starting emergency generator by battery failed.
Action required: 705 - Other - as specified
Resolved 16 April 2017
Resolution: Vessels crew troubleshooted the battery bank and its' connections. After a brief period, crew were able to successfully start on the second source of battery power.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.