MAURY USCG vessel records
← All vessels

CMA CGM HOMERE

CMA CGM HOMERE is a freight ship. The Coast Guard has recorded 33 inspections since 2017, most recently in July 2026, along with 4 deficiencies and 25 operational controls, 3 with no removal date recorded.

Records from 2017 to 2026. Most recent: operational control imposed, 25 July 2026.

Built
Not recorded
Last inspected
25 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
3 with no removal date recorded

Identity

9362322
1436120
Flag
INDONESIA
Maury page id
psix-1436120

Inspections, by type

…with no type recorded26
Years with a record 4 calendar years (2017–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it7181 - Convention (Subpart B), Net Ton
21264 - Dead Weight, Metric Ton
17594 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 33

25 July 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8446132
10 July 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8434778
23 June 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8410532
21 June 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8409339
4 June 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8391065
14 May 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8373000
30 April 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8358607
10 April 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8345892
12 March 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8325308
19 February 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8312831
2 February 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8305029
1 February 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8304558
9 January 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8293951
11 December 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8282163
25 November 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8273804
19 November 2025 PSC B · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8270977
20 October 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8255491
26 September 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8241858
8 September 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8229660
17 August 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8211691
28 July 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8195020
3 July 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8174090
13 June 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8158788
26 May 2025 PSC B · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8143437
23 May 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8142368
13 April 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8110808
27 March 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8100685
10 March 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8091084
23 January 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8068904
27 December 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8051383
23 December 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8050504
19 November 2024 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8032394
17 April 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6124367

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 May 2025 Resolved
After any survey of the ship under artical 14 has been completed, no change shall be made in the structure...without the sanction of the administration. Master could not provide evidence of approved repair to large/deep inset in hull on port quarter of the vessel. ILLC (88 Proto) 8 Art. 15
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2025
Resolved 12 June 2025
Resolution: Received, reviewed and accepted BV report of vessels plans to conduct permanent repairs at next drydock 22APR2027 and temp repair was found satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 26 May 2025 Resolved
The condition of the shi and its equipment shall be maintained to conform with the provisions of the present regulations... Obsurved natural supply vent cover cover for NO. 6 cargo hold near bay 25 damaged. 76 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2025
Resolved 12 June 2025
Resolution: Received, reviewed and accepted BV report attesting to vent cover properly repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 December 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board... The maneuvering system control air dryer in the main engine inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2025
Resolution: Received pictures from vessel showing install and operation of replacement air dryer.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 19 November 2024 Resolved
A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. Second source of start was not effective. PSCO observed crew attempt unsuccesful hydraulic pump start. Crew brought pressure up to 300 bar rendering a successful attempt. 74SOLAS(2004)II-1/44.2
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 November 2024
Resolution: Crew brought pressure up to 300 bar rendering a successful attempt.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.