Records from 2017 to 2024. Most recent: inspection, 28 March 2024.
Inspection history · 10
28 March 2024
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7886688
31 March 2023
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7660454
13 April 2022
Drydock Exam · Hull Examination · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7426079
1 April 2021
Hull Examination · Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7164918
13 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6752721
3 November 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6596999
19 August 2018
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6522025
12 August 2018
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6512968
24 July 2017
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6221578
1 February 2017
Construction Oversight · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6122832
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2024
No resolution recorded
First aid equipment was found with expired equipment.
Replace first aid kits.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2024
No resolution recorded
During the overpressure stress test, the vessel did not hold pressure in the chambers being measured, indicating a slow but significant leak between the baffles.
To receive dry dock credit; identify the source of the leaks, propose adequate repairs and once repairs are executed, make the vessel available for additional pressure testing of 1.5 times the working pressure for 10 minutes verified via calibrated pressure gauge.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 March 2024
No resolution recorded
Radar reflector was reported as warped and is on order to be replaced. Send proof of replacement.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 28 March 2024
No resolution recorded
The batteries in the portable lights were corroded and the portable lights were no longer operations. Replace the flashlights and send proof of the replacement.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 March 2024
No resolution recorded
The line for the ring buoy line is wasted. Replace ring buoy line and send proof of replacement to the OCMI to clear the deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 July 2019
Resolved
Provide radar reflector as per D17INST 16711 date
14DEC2018 before next 2020 operating season in AK
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 1 April 2021
Resolution: Verified equipment onboard.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 August 2018
Resolved
Prove Port speed tube holds air.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 August 2018
Resolution: Port fill tube to speed tube connections was found to be leaking. Connection point was broke down and resealed. Witnessed a satisfactory air test.