MAURY USCG vessel records
← All vessels

V TRE

V TRE is a 2017 freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in April 2024, along with 11 deficiencies.

Records from 2017 to 2024. Most recent: inspection, 2 April 2024.

Built
2017
Last inspected
2 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9706580
9HA4476
1436780
Flag
MALTA
Maury page id
psix-1436780

Documentation record

Tonnage as PSIX records it12725 - Convention (Subpart B), Net Ton
37888 - Dead Weight, Metric Ton
46718 - Displacement, Metric Ton
23689 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

2 April 2024 In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7888517
21 March 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7883013
17 March 2023 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7652511
18 January 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7623359
5 January 2023 PSC B · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7614511
30 December 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7614638
24 August 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6515043
11 May 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6137821

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 January 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed missing service straps for all liferafts. PSCO could not verify serviceability and operational readiness in the event of an emergency. 74SOLAS20 III/20.2 (17A/C)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2023
Resolved 10 January 2023
Resolution: VSL was attended by SERVITEC Liferaft tech to reband and restrap all liferafts onboard. Class completed remote survey, and verified that they were satisfied with the solution. USCG is satisfied by class report.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 January 2023 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. PSCO observed exposed electrical wiring within the 440V junction box for a hydraulic pump unit and the associated breaker was in the "ON" position. PSCO observed missing indicator switch for a 440V connection in the Gyro Room. Additionally, there were missing electrical switches in the Gyro Room for 220V connections as well as deck electrical switches for 220V connections, light fixtures, and deck house light fixtures. Vessel did not properly implement tag-out procedures to prevent electrical shock. 16A/C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2023
Resolved 18 January 2023
Resolution: Class Report received detailed electrical repairs and implementation of tagout/lockout procedures.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 January 2023 Resolved
To prevent the ignition of combustible materials or flammable liquids, means shall be provided to limit the accumulation of flammable vapours. PSCO observed Gasoline cans and sealing foam aerosol cannisters were found in #1 Mast House without fixed fire suppression. 74SOLAS20 II-2/4.1.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 January 2023
Resolved 5 January 2023
Resolution: Gasoline cans and sealing foam cannisters moved to paint locker.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 January 2023 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, e.g. in compartments assigned principally to accumulator batteries, in paint lockers, acetylene stores or similar spaces, unless the Administration is satisfied that such equipment is appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. PSCO observed cracked explosion-proof light fixture in the paint locker. 74SOLAS20 II-1/45.10.4 (16a/c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2023
Resolved 18 January 2023
Resolution: Class Report detailed new light fixture in the paint locker.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 January 2023 Resolved
Except as permitted by the Administration in exceptional circumstances, all metal sheaths and armour of cables shall be electrically continuous and shall be earthed. PSCO observed multiple wasted bonding straps on deck for ventilation shrouds, crane E-stops, and 220V junction boxes. 74SOLAS20 II-1/45.5.1 (16 a/c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2023
Resolved 18 January 2023
Resolution: Class Report detailed repairs were carried out for bonding straps for vessel equipment.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 5 January 2023 Resolved
An emergency means comprised of either fixed or portable equipment or both shall be provided for two way communications between emergency control stations, muster and embarkation stations and strategic positions onboard. PSCO observed flying bridge speaker unwired in damaged junction box as well as aft freefall lifeboat speaker cables left hanging and unwired. PSCO also observed missing communications speaker for emergency towing, mooring, and general communications. 74SOLA20 III/6.4.1 (16 a/c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2023
Resolved 17 March 2023
Resolution: Vessel provided satisfactory Class Report, photographs/videos. Deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 5 January 2023 Resolved
The administration shall be satisfied that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained. PSCO observed the float-free VDR hydrostatic release unit and VDR capsule battery to be expired. 74SOLAS20 V/16.1 (16a/c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2023
Resolved 17 March 2023
Resolution: Vessel provided satisfactory Class Report, photographs/videos. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 January 2023 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed forward starboard fire hydrant gauge wasted and non-operational 74SOLAS20 II-2/14.2.2.1 (50a/c)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2023
Resolved 18 January 2023
Resolution: Class Report detailed replacement of wasted fire hydrant pressure gauge with a new one.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 August 2018 Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods. Vessel did not use their ballast water treatment system and only did a mid-ocean exchange. 33CFR151.2025(a) 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 September 2018
Resolved 5 January 2023
Resolution: Vessel utilizes ballast water treatment system iaw 46CFR162.060. USCG certificate of approval for BWMS 162.060/12/0, expires 06Nov2023.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 11 May 2017 Resolved
Before the ship leaves port and at all times during voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that fuel level on both rescue boat fuel tanks were below 1/4 of a tank. 74 SOLAS (14) CH III 20.2 10c
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 11 May 2017
Resolution: [name withheld] had crew fill up both rescue boat fuel tanks on the spot.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 May 2017 Resolved
The safety-management system shall be maintained in accordance with the provisions of the ISM Code. PSCO observed that weekly checklist for fuel level was checked off as being full 05 days ago. PSCO observed that the weekly checklist was filled out as being completed for the rest of the month. Provide evidence that proper checklists are being performed IAW company policy. 74 SOLAS (14) CH IX 5 50a
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 12 May 2017
Resolution: Recieved report from RINA clearing deficiency. Vesel created new checklist that included fuel readings and crew trainrd on new checklist procedure.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.