Records from 2017 to 2025. Most recent: inspection, 1 December 2025.
Inspection history · 14
1 December 2025
Administrative Inspection · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8272442
5 October 2025
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 8257999
29 March 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8106701
27 February 2025
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8086562
27 November 2024
Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8040940
17 January 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7846735
25 February 2023
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7642028
31 January 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7666266
8 November 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7592416
16 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7412991
14 October 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7333072
22 April 2021
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7199467
30 December 2020
Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7200686
18 March 2017
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6123313
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2025
Resolved
A vessel not required to have a power-driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI. Vessel only had 1 fire bucket. Item corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 27 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2025
Resolved
It was determined that vessel is required to have the following portable extinguishers:
-One (01) 10 B:C extinguisher at operating station
-One (01) 40 B:C extinguisher for machinery space
Vessel had two (02) 10 B:C extinguishers at time of inspection. Must replace one (01) 10 B:C extinguisher with one (01) 40 B:C extinguisher. Item corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 27 February 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 February 2025
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel operators must provide proof of annual maintenance for portable fire extinguishers to USCG. Item corrected on the spot with purchase of two (02) new fire extinguishers.
Action required: 10 - Deficiency Rectified
Resolved 27 February 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 March 2022
Resolved
The OCMI may require that a vessel and its equipment meet any test or inspection deemed necessary to determine that they are suitable for the service in which they are to be employed. Vessel identifies monthly examinations of ground level rigging equipment in PMP, however did not a means to record what was checked, on what date, by whom. Identify monthly maintenance checklist in accordance with NVIC 02-16.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 30 March 2022
Resolution: PMP developed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 March 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 30 March 2022
Resolution: Light list onboard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022
Resolved
Battery installations must be mounted too protect against shifting of the vessel and free from exposure to water splash or spray. No battery boxes (2).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 30 March 2022
Resolution: Battery boxes/covers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2022
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Countless wires unsupported in near battery underneath the helm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2022
Resolved 30 March 2022
Resolution: Wires organized and supported.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Brackets for 10 BC portable fire extinguishers are missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 30 March 2022
Resolution: Proper mounting brackets installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 March 2022
Resolved
Each hatch exposed to the weather must be watertight. Two deck hatches lacks securing devices and captive chain.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 30 March 2022
Resolution: Deck hsatches have securing latches and securing chains attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) and UL 1113 approved. Bilge pumps are not UL 1113 approved.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2022
Resolved 30 March 2022
Resolution: UL 1113 approved submersible bilge pumps installed.