MAURY USCG vessel records
← All vessels

BUNUN JUSTICE

BUNUN JUSTICE is a freight ship. The Coast Guard has recorded 6 inspections since 2017, most recently in March 2024, along with 2 deficiencies and 1 operational control.

Records from 2017 to 2024. Most recent: inspection, 22 March 2024.

Built
Not recorded
Last inspected
22 March 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9732448
1437767
Flag
PANAMA
Maury page id
psix-1437767

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2017–2024)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it23239 - Convention (Subpart B), Gross Ton
46314 - Displacement, Ton
37748 - Dead Weight, Ton
12101 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 6

22 March 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7874785
15 August 2022 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7534257
29 July 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7520491
28 July 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7518435
23 June 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7228212
15 May 2017 Ballast Water Examination · PII Safety Exam · Administrative Inspection · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6139140

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2024 Resolved
All electric cables and wiring external to equipment shall be at leas of flame-retardant type and shall be so installed as not to impair their original flam-retarding properties. PSCO observed improper wiring and exposed wires leading to SCBA bottle charger. SOLAS II-1/45.5.2, Code 16A
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2024
Resolved 22 March 2024
Resolution: Received, reviewed and accepted proper documentation and photo evidence from chief engineer and flag state stating the deficiency was rectified. Ships crew replaced defecient wiring to SCBA bottle charger.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 22 March 2024 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs, means of excape systems and appliances. PSCO observed quick firing strap not attached to EEBD’s. SOLAS II-2/14.2.1.1.3, Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2024
Resolved 22 March 2024
Resolution: PSCO observed crew attach quick firing straps to all EEBD's on board.

Ownership record