MAURY USCG vessel records
← All vessels

ACADIA EXPLORER

ACADIA EXPLORER is a 2018 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2018, most recently in May 2026, along with 13 deficiencies and 1 casualty investigation in 2020.

Records from 2018 to 2026. Most recent: inspection, 4 May 2026.

Built
2018
Last inspected
4 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9851660
WDK2773
1439623
Flag
UNITED STATES
Maury page id
psix-1439623

Documentation record

Registered dimensions (L × B × D)92.0 ft × 28.0 ft × 9.8 ft
Registered tonnagegross 87 / net 49
ITC dimensions (L × B × D)92.0 ft × 28.0 ft × 9.8 ft
ITC tonnagegross 231 / net 69
BuilderGULF CRAFT LLC · FRANKLIN, LA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBAR HARBOR, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it231 - Convention (Subpart B), Gross Ton
87 - Regulatory (Subpart C or D), Gross Ton
69 - Convention (Subpart B), Net Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

4 May 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8356305
13 April 2026 Internal Structural Exam · Vessel Attendance · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8353493
2 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8226359
17 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7914374
29 March 2024 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7888945
22 May 2023 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7672333
6 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7576992
23 February 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7400701
23 June 2021 Annual Inspection · Internal Structural Exam · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7232560
18 March 2021 Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7185539
20 November 2020 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7101938
10 August 2020 Internal Structural Exam · DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7035419
21 January 2020 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6892977
13 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6888731
2 May 2019 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6675480
12 June 2018 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6441906
5 March 2018 Initial Certification · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6366360

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2026 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. All of the vessel's fire protection equipment have servicing that was expired. Service fire protection equipment prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2026
Resolution: All of the fire equipment on board was serviced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 May 2026 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The portable lights on the vessel were inoperable. Fix or repair the lights to the satisfaction of the attending marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 4 May 2026
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 4 May 2026 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. The vessel type III MSD was unsecured. Make arrangements to secure MSD to the satifaction of the attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 4 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 May 2023 Resolved
Found corrosion resistant clip frozen / inop, repair replace with corrosion resistant clip on float light lanyard.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2023
Resolved 23 May 2023
Resolution: New clip installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 May 2023 Resolved
Found fire pump gauge inop, repair replace, prove proper operation of port hull fire/bilge pump gauge.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2023
Resolved 23 May 2023
Resolution: New gauge installed and pump test sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2019 Resolved
Prove operation of port high level alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 June 2019 Resolved
Repair/Replace EPIRB antenna.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 21 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2019 Resolved
Install detachable clip on ring buoy waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 21 June 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 June 2019 Resolved
Provide servicing certificate for fixed and portable systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2019 Resolved
Address low voltage issue on #2 generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2019
Resolved 21 June 2019
Operations/Management › Drills/Instruction › Fire
Issued 1 June 2018 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar wiht his or her duties in case of a fire. Once the vessel has arrived in Bar Harbor, Maine OCMI zone, they shall coordinate with the local Coast Guard office to perform a fire drill.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2018
Resolved 21 June 2018
Resolution: Drills conducted.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 June 2018 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with thier duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Once the vessel arrives in Bar Harbor, Maine OCMI zone, they shall coordinate with the local Coast Guard office to perform an abandon ship drill and a man over board drill.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2018
Resolved 21 June 2018
Resolution: Drills conducted.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 1 June 2018 Resolved
The owner of a vessel rquesting initial inspection for certification shall, prior to the start of construction: submit for approval to the cognizant OCMI, at least two copies of the following plans: Machinery installation to include but not limited to: propulsion and propulsion controls... Owner shall submit Design Verification and Testing Procedures (DVTP) as per CG-CVC Policy letter 17-07 to the Marine Safety Center for review/approval.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 13 September 2018
Resolution: DVTP have been approved by MSC.

Casualty record · 1

20 November 2020Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7101938
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.