← All vessels
PACIFIC RAWAN
PACIFIC RAWAN is a tank ship. The Coast Guard has recorded 3 inspections in 2026, along with 2 deficiencies — 2 with no resolution recorded —.
Records in 2026. Most recent: inspection, 20 June 2026.
- Built
- Not recorded
- Last inspected
- 20 June 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9772022 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7WP7
1439836
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1439836
Inspections, by type
The 3 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it62397 - Convention (Subpart B), Gross Ton
109999 - Dead Weight, Metric Ton
129362 - Displacement, Metric Ton
33386 - Convention (Subpart B), Net Ton
109999 - Dead Weight, Metric Ton
129362 - Displacement, Metric Ton
33386 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 3
20 June 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8407937
20 June 2026
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8413147
5 May 2026
COC-TVE Renew · PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8367262
Deficiency record · 2
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 June 2026
No resolution recorded
Maintenance, testing and inspections shall be carried out based on the guidelineas devloped by the organization* and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. PSCO recieved report that vessels fixed CO2 extinguishing system was non compliant with the requirements as per MSC.1/CIRC. 1318 requiring at the at least 10% of the total number provided of high pressure cylinders be subjected to an internal inspection and hydrostatic test at the 10 year mark. Initial due date was 14JUN2026.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 June 2026
No resolution recorded
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization* and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO received report that vessel's fixed CO2 extinguishing system was non compliant with the requirements as per MSC.1/Circ. 1318 requiring at least 10% of the total number provided of high-pressure cylinders be subjected to an internal inspection and hydrostatic test at the 10 year mark.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.