Records from 2018 to 2026. Most recent: inspection, 25 March 2026.
Documentation record
Registered dimensions (L × B × D)92.0 ft × 28.0 ft × 9.8 ft
Registered tonnagegross 87 / net 49
ITC dimensions (L × B × D)92.0 ft × 28.0 ft × 9.8 ft
ITC tonnagegross 231 / net 69
BuilderGULF CRAFT LLC · FRANKLIN, LA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it231 - Convention (Subpart B), Gross Ton
87 - Regulatory (Subpart C or D), Gross Ton
69 - Convention (Subpart B), Net Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
25 March 2026
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8330469
12 November 2025
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8267217
3 December 2024
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8033595
26 June 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7964022
18 April 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7891608
18 March 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875967
11 October 2023
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7802487
6 September 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7554033
23 February 2022
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7400705
30 August 2021
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7300554
28 September 2020
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7066886
21 January 2020
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6892984
13 January 2020
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6888688
10 September 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6808065
21 May 2019
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6703745
1 October 2018
Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6552209
30 August 2018
In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6527139
31 May 2018
Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6430685
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Vessels waterlight battery was expired. Replace battery. Correct deficiency within 7 days after which vessel will be limited to day-time operations.
Action required: 705 - Other - as specified
Due 24 November 2025
Resolved 19 November 2025
Resolution: Operator replaced life buoy waterlight.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2024
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Pressure gauge on both fire pumps were inoperable during inspection. Repair or replace gauges to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2025
Resolved 17 December 2024
Resolution: Operator replaced gauges
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2024
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The vessel has cartridge type fuses behind the operating station console that are not UL listed. Replace with UL listed fuses to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2025
Resolved 30 January 2025
Resolution: Verified fuses are UL listed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2024
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The vessel has blade type fuses behind the operating station console. Replace with UL listed cartridge fuses to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2025
Resolved 30 January 2025
Resolution: OCMI confirmed that the blade fuses are protected upstream by approved UL breakers in accordance with approved plans.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 3 December 2024
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Both hydrostatic releases on installed life rafts were marked to be expired during inspection. Replace hydrostatic release units to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2025
Resolved 17 December 2024
Resolution: Operator replaced hydrostatic release units
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 September 2022
Resolved
Prove operation of port fuel void high level alarm lamp.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 7 November 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 September 2022
Resolved
Replace expired items in galley first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 4 October 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 October 2020
Resolved
Conducet U/W drills.
Action required: 705 - Other - as specified
Due 1 April 2021
Resolved 6 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 October 2020
Resolved
Make bilge system (pumps and alarms) available for inspection and testing.
Action required: 705 - Other - as specified
Due 1 April 2021
Resolved 6 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 October 2020
Resolved
Make main propulsion engine and generators available for inspection.
Action required: 705 - Other - as specified
Due 1 April 2021
Resolved 6 September 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 October 2020
Resolved
Provide fire servicing for fixed and portable equipment.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2021
Resolved 30 August 2021
Resolution: Completed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 October 2020
Resolved
Provide servicing report for detection system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2020
Resolved 13 October 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 October 2020
Resolved
Update expired first aid kit items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 30 August 2021
Resolution: Expired meds updated.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 September 2019
Resolved
Register EPIRB. Vessel Restricted to operating not more than 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 30 October 2019
Resolved 2 October 2019
Resolution: EPIRB Registered.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 7 October 2018
Resolved
The Master, or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meets paragraph (b) of this section is on the ship and that each personhandling garbage follows the plan. The vessel didn't have a garbage management plan specific to Puerto Rico.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 October 2018
Resolved 8 October 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 October 2018
Resolved
Vessel must provide proof of EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 October 2018
Resolved 8 October 2018
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 October 2018
Resolved
All cable and wire must be protected from chaffing/fraying. The vessel had exposed wiring on the topside deck.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 October 2018
Resolved 8 October 2018
Resolution: Corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 August 2018
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Once the vessel has arrived in Puerto Rico OCMI zone, they shall coordinate with the local Coast Guard officed to perform a fire drill.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2018
Resolution: Conducted satisfactory fire drill during COI inspection.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 27 August 2018
Resolved
The master shall conduct sufficient drills and give sufficient instruction to make sure that all the crew members are familiar with thier duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Once the vessel arrives in the Puerto Rico OCMI zone, they shall coordinate with the local Coast Guard office to perform an abandon ship drill and a man overboard drill.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2018
Resolution: Conducted satisfactory man overboard/abandon ship drills during COI inspection.