Records from 2017 to 2025. Most recent: inspection, 7 April 2025.
Documentation record
Registered dimensions (L × B × D)47.0 ft × 17.0 ft × 8.5 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderB & T WELDING LLC · BOOTHVILLE, LA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
7 April 2025
Annual Inspection · Deficiency Check · Damage Survey · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8106616
7 April 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8106734
18 October 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8020987
1 July 2024
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7946443
4 January 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7840156
27 September 2022
COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7528014
7 October 2021
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7314425
10 November 2020
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7078471
13 December 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6865637
14 November 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6580984
10 May 2017
Construction Oversight · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6143170
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 August 2025
Resolved
OMO shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended.
During underway steering test, the vessel's master lost maneuverability. MI's also observed water starboard rudder post in the lazarette in a slow-acting steering ram. Make satisfactory repairs to the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 August 2025
Resolved 15 August 2025
Resolution: Rudder was repacked,and the steering system was bled of air. Conducted underway maneuverability test, sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 April 2025
Resolved
The vessel was involved in a marine casualty and sustained extensive damage to the hull, resulting in flooding of the engine room and steering compartment. The vessel's structural integrity has been compromised, and the extend of damage raises significant concerns regarding watertight integrity, stability, and safe operation. A comprehensive survey must be conducted and a repair plan be submitted and accepted by the Coast Guard for review. The vessel is restricted from operations until the requirement is met and verified by a Marine Inspector. Submit a detailed hull damage survey and proposed repair plan. Repairs must be completed to the satisfaction of the OCMI and verified prior to resuming operations.
46 CFR 177.100
60c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 14 August 2025
Resolution: While onboard, the team verified the condition of the genset fuel line fittings, bilge pump PTO, and verified servicing had been completed for the pre-engineered fire extinguishing system. All identified issues have been satisfactorily repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 July 2024
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Coast Guard received a report of water ingress in the engine room through the stern tube. After further investigation it was determined that there is a crack beneath the waterline with a steady stream of water ingress.
Vessel must submit a repair plan and complete repairs satisfactory to the attending Marine Inspector prior to vessel movement.
46 CFR 185.100
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 15 July 2024
Resolved 8 August 2024
Resolution: Recieved photographs attesting to proper repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 May 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Marine Inspector was made aware that the generator was being replaced, but no plans or timeline has been given. In order to meet the approval of the OCMI, an inspection is required to be conducted on the new generator prior to operation.
46 CFR 176.700(a)
Action required: 705 - Other - as specified
Resolved 23 June 2023
Resolution: Inspector witnessed new generator onboard with an ambient temp of 40°C and generator has been derated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 May 2023
Resolved
In addition, the owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, at least two copies of the following: Electrical installation including, type and size of generators and prime movers; power, lighting, and interior communication panelboards with number of circuits and rating of energy consuming devices; rating of circuit breakers and switches, interrupting capacity of circuit breakers, and rating and setting of overcurrent devices; and electrical plant load analysis.Marine Inspector was made aware that the generator was being replaced, but none of the above mentioned plans were submitted. Provide the listed above plans before installation/operation of the generator for approval.
46 CFR 177.202(b)(4)
Action required: 705 - Other - as specified
Resolved 23 June 2023
Resolution: Inspector witnessed new generator onboard with an ambient temp of 40°C and generator has been derated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 September 2022
Resolved
Each generator and motor must be designed for an ambient
temperature of 50°C (122 °F) or meet the requirements of
46 CFR 183.320(b)(1) or (2).
Inspectors witnessed generator rated to 40°C. Provide
proof of generator meeting the requirement stated above
to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 June 2023
Resolution: Inspector witnessed new generator onboard with an ambient temp of 40°C and generator has been derated.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 October 2021
Resolved
(a) Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead.
Various broken welds identified in the stern void. Two cracked welds below the waterline on the aft bulkhead are compromising watertight integrity.
Submit repair proposal and conduct permanent repairs to damaged identified during inspection. To be cleared to the satisfaction of the Coast Guard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 October 2021
Resolution: Inspected all repairs in aft steering gear compartment in narative and attached repair plan to include completion of successful dye pen test for leaks of Two (2) 7" cracks on aft bulkhead, one (1) on either side of rerescue ladder stairs at the waterline
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 October 2021
Resolved
(b) A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section.
Pre-Engineered fire system was not able to be manually reset.
Conduct appropriate repairs to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 October 2021
Resolution: Tested Fire Buoy System to include testing override of automatic engine shut-off. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 November 2020
Resolved
Weathertight aluminum doors for the cockpit were warped and didn't provide a complete seal at the top of the doors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2020
Resolved 7 January 2021
Resolution: Vsl rep sent pictures of the doors properly sealing after they were bent back into proper shape and the gasket material was replaced.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 December 2018
Resolved
Found Fixed Fire Extinguisher in the engine room not installed as per manufacturer's specifications due to a cut out on port and stbd top deck of compartment forward of engine room. This opening creates a continuous space protected by the installed Fixed fire ext. greater than specified by the manufacturer. Repair system to the satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2019
Resolved 9 January 2019
Resolution: Cut outs covered permanently.