Records from 2017 to 2025. Most recent: inspection, 12 December 2025.
Documentation record
Registered dimensions (L × B × D)86.3 ft × 20.7 ft × 7.7 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)86.3 ft × 20.7 ft × 7.7 ft
ITC tonnagegross 76 / net 37
BuilderGRAVOIS BOATS LLC · FRANKLIN, LA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWASHINGTON, DC
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Convention (Subpart B), Gross Ton
61 - Regulatory (Subpart C or D), Gross Ton
37 - Convention (Subpart B), Net Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
12 December 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8285161
2 May 2025
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8236368
21 November 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8046071
11 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7955737
6 July 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7952805
24 March 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7884162
24 March 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7892351
14 December 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7839052
19 April 2023
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7671513
14 June 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7477402
23 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7400993
8 December 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7364777
22 October 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7085232
30 January 2020
In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6904799
12 December 2019
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6868785
9 July 2019
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6743201
5 March 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6639876
12 December 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6597270
30 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6402732
18 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6394711
16 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6392208
14 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6391832
14 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6391971
7 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6387445
27 February 2018
Construction Oversight · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6364111
31 October 2017
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6299356
26 October 2017
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6299383
6 October 2017
Initial Certification · In-Service Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6278796
11 September 2017
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6264415
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Vessel reported a loss of power to the Starboard Main Engine.
46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2024
Resolution: A technician attended the vessel and completed successful sea trials.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel Operator reported an allision with another vessel causing damage to the vessels exhaust pipe and deck railing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Repairs were made to the satisfactio of the attending CG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 October 2020
Resolved
Vessels more than 65 ft must be provided with 2 fixed power pumps with minimum capacity per pump of 50 gal/min. Port fixed power bilge pump was unable to take suction from bilge pickup.
46 CFR 182.520(a)
Table 182.520(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 6 November 2020
Resolution: Observed port fixed power bilge pump take suction and operate satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 December 2019
Resolved
Fuel leaks were found on port and starboard fuel tank sounding gages on the lower valves. Fuel leak found on port fuel return coupling in port fuel tank space. Fuel leak found on starboard fuel supply coupling at aft end of the starboard fuel tank space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 25 February 2020
Resolution: Starboard side coupling replaced and CG conducted pneumatic test to ensure there were no leaks, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 December 2019
Resolved
Accumulation of diesel fuel was found on the outboard side of the starboard keel within the power distribution panel compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 14 December 2019
Resolution: Diesel fuel was cleaned up to the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2019
Resolved
A nonconducting mat or grate was not observed in front of the power distribution panel contained in the starboard hull.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2019
Resolved 14 December 2019
Resolution: Platform with nonconducting mat installed - ALL SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2019
Resolved
Provide this office with proof of satisfactory repairs to the "Reduction of Propulsion" incident that occurred to the vessel's STBD Main Engine. Vessel will need to conduct satisfactory OP Test and Sea Trials in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 11 March 2019
Resolution: Coast Guard Marine Inspector witnessed the proper operation of the starboard engine and starboard fuel shutdown system, ALL SAT.
Construction/Loadline › Penetrations › Weld
Issued 27 February 2018
Resolved
Starboard side: top hydraulic pipe passing through watertight bulkhead failed air test. Portside: bottom hydraulic pipe passing through watertight bulkhead failed air test.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 27 April 2018
Resolution: Starboard and port hydraulic piping passing through watertight compartments were successfully air tested.