GAS STELLA is a 2017 tank ship. The Coast Guard has recorded 14 inspections since 2017, most recently in January 2026, along with 3 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: inspection, 8 January 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it55001 - Dead Weight, Ton 14469 - Convention (Subpart B), Net Ton 73634 - Displacement, Ton 48229 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 14
8 January 2026Administrative Inspection · PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8291131
14 February 2025COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8075085
16 May 2024Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7913629
10 January 2024COC-GAS Renew · Administrative Inspection
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 23 September 2019Resolved
The company should establish procedures, plans and instructions including checklists, as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel.
Vessel did not treat ballast water on board per U.S. regulations. The vessels ballast water management plan (BWMP) has clear guidance on local regulations, however, the company provided "Check list for vessels calling US/Canadian Ports, form OP-17" has conflicting information that does not inform the master of BWM Practices.
74SOLAS(14) IX/3.1
ISM Code Part A/7
50ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 October 2019
Resolution: Company updated check list and sent fleet wide notices. See attached documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 September 2019Resolved
Certified safe type equipment may be fitted in gas dangerous spaces and zones in accordance with the following provisions. Instrinsically safe electrical equipment and qiring may be fitted in all gas dangerous spaces and zones as defined in 1.3.17.
Inside cargo compressor room, on the stbd side aft bulkhead, the fresh water and sea water cooling pump start switches were found to have no intriscially safe seals where the wires entered the terminal box. The circuits and wiring could be seen from below the box through an open hole approximately 30-40 mm wide. Crew temporarily sealed the fitting with putty.
74SOLAS(14) VII/13.1
IGC 10.2.1
40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 October 2019
Resolution: Company and class proved proper installation with a gap of 12.5 mm. See attached documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2019Resolved
The master, owner, operator, agent or person in charge of a vessel equipped with ballast tanks that operates in the water of the United States must employ one of the following ballast water management methods: install and operate a ballast water management system that has been approved by the Coast Guard.
Vessel conducted untreated empty refill excnahge after compliance date listed in 33 CFR 151.2035(b).
33 CFR 151.2025(a)(1)
40c
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 December 2019
Resolution: Vessel company modified checklists to include the mandatory use of BWTS while in the US.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.