MAURY USCG vessel records Sign in
← All vessels

TILAPIA

TILAPIA is a 1976 offshore supply vessel. The Coast Guard has recorded 42 inspections since 1990, most recently in January 2022, along with 23 deficiencies and 2 casualty investigations between 2011 and 2012.

Records from 1990 to 2022. Most recent: inspection, 10 January 2022.

Built
1976
Last inspected
10 January 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH5368
144316
Flag
UNITED STATES
366818140, 367058090, 367627270 (licence lapsed)
Maury page id
psix-144316

Inspections, by type

…with no type recorded5
Years with a record 24 calendar years (1990–2022)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it97 - Simplified, Gross Ton
78 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH5368MMSI 367627270 · expired · compulsorily equipped · granted 13 June 2014, cancelled 17 August 2024
WDC6578MMSI 367058090 · expired · compulsorily equipped · granted 22 July 2005, cancelled 26 September 2015
WDA5254MMSI 366818140 · cancelled · compulsorily equipped · granted 6 July 2001, cancelled 31 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCV8459MMSI not assigned · expired · compulsorily equipped · granted 1 February 1999, cancelled 1 April 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCQ4394MMSI not assigned · expired · voluntarily equipped · granted 24 March 1995, cancelled 28 May 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT. JOE Commercial Fishing Vessel · MISLE 51390 · 23 August 1993 · activity 140548

Inspection history · 42

10 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7378224
3 December 2015 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5774842
16 June 2012 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4345751
23 May 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4318690
13 February 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4250682
7 September 2011 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4137467
28 July 2009 Re-Inspection · Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3548359
25 September 2008 MTSA Verification · Annual Inspection · Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3332409
25 March 2008 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3172467
15 February 2007 Hull Examination · Ballast Water Examination · Internal Structural Exam · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2871914
8 October 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2796526
2 August 2006 COI Inspection · Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2733684
23 November 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539961
17 February 2005 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2294719
23 November 2004 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2246819
26 January 2004 Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1994086
25 November 2003 Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1954297
27 May 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1802516
14 February 2002 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1488402
28 February 2001 Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466190
18 January 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451493
1 October 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041799
23 June 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883972
7 May 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453608
4 March 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411620
30 May 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400583
15 March 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385658
13 February 1995 Hull Examination · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414407
8 November 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213929
27 April 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165401
28 January 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1379900
23 August 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 140548
13 August 1993 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1158636
18 March 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 834234
5 February 1993 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473068
15 July 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 962099
10 February 1992 COI Inspection · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957772
6 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 910902
13 March 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926763
23 May 1990 Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924024
31 March 1990 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241454
14 February 1990 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243283

Deficiency record · 23

Deck/Cargo › Cargo Transfer (solid) › General
Issued 3 December 2015 Resolved
Crane must be tested at both the maximum and minimum boom angles. Provide documentation to the satisfaction of the MI.
Due 7 January 2016
Resolved 8 December 2015
Resolution: Documentation provided. Def cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 3 December 2015 Resolved
Clean windings on STBD generator.
Due 7 January 2016
Resolved 8 December 2015
Resolution: windings cleaned to inspector satisfaction. def cleared.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 December 2015 Resolved
Clean galley range vent and screens.
Action required: 705 - Other - as specified
Due 7 January 2016
Resolved 8 December 2015
Resolution: Documentation provided. Cleared.
Construction/Loadline › Structures › Door
Issued 3 December 2015 Resolved
Adjust 01 deck weather tight door to seal properly.
Action required: 705 - Other - as specified
Due 7 January 2016
Resolved 8 December 2015
Resolution: Documentation provided. Cleared.
Engineering › Pressure Vessel › Piping
Issued 3 December 2015 Resolved
Repipe relief valve from hot water heaters to drain into bilge.
Action required: 705 - Other - as specified
Due 7 January 2016
Resolved 8 December 2015
Resolution: Documentation provided. Def Cleared.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 December 2015 Resolved
Properly blank off distribution panel in galley and label amperages.
Action required: 705 - Other - as specified
Due 7 January 2016
Resolved 4 January 2016
Resolution: Documentation Provided. Cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 December 2015 Resolved
Repair stern light and red restricted maneuverability lights.
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 8 December 2015
Resolution: Documentation provided. Def cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 7 September 2011 Resolved
Demonstrate proper op of port generator overspeed.
Action required: 705 - Other - as specified
Resolved 8 September 2011
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 September 2011 Resolved
Replace e-light stbd side e/r
Action required: 705 - Other - as specified
Resolved 8 September 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 September 2011 Resolved
Replace reflector tape where peeled off on all lifebuoys
Action required: 705 - Other - as specified
Resolved 8 September 2011
Engineering › Lubricating Oil Service System › Piping
Issued 2 August 2006 Resolved
Per NVIC 8-91 vessel hydraulic jacking system must substantially meet the requirements of 46 CFR 58.30 and 56.30. Provide 3rd party inspection of all system components to identify systems as "fail safe" and any components not rated for maximum system operating pressure. Repair/replace all identified components. Provide approved (MSC) plans of vessel hydraulic system prior to next annual inspection
Action required: 705 - Other - as specified
Due 14 February 2007
Resolved 4 April 2007
Resolution: Sytem fittings changed to meet 46CFR58.30 and 56.30.
Lifesaving
Issued 7 May 1999 Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District's policy "Rescue Boat Requirements on Offshore Supply Vessels" dated 12NOV98 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Construction/Loadline
Issued 13 February 1995 Resolved
MAKE WATERTIGHT EMERGENCY ESCAPE HATCH TO ENGINE ROOM. AND LABEL THE SAME.
Condition: Unknown
Due 21 February 1995
Resolved 16 February 1995
Engineering
Issued 13 February 1995 Resolved
PROVE PROPER OPERATION OF OVERSPEED SHUT-DOWN OF BOTH MAIN ENGINES.
Condition: Unknown
Due 21 February 1995
Resolved 16 February 1995
Documentation
Issued 5 February 1993 Resolved
PUT COMPLETE INTERIM OPERATING MANUAL ONBOARD VESSEL.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Construction/Loadline
Issued 5 February 1993 Resolved
PROPERLY LABEL BILGE/BALLAST SYSTEM VALVES.
Condition: Unknown
Due 19 February 1993
Resolved 3 March 1993
Construction/Loadline
Issued 5 February 1993 Resolved
RAISE SUCTION PIPE FOR ENGINE ROOM BILGE SUCTIONS.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Engineering
Issued 5 February 1993 Resolved
REPLACE PLASTIC SIGHT GLASSES WITH PROPER SIGHT GLASSES IN STBD ENGINE ROOM.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Navigation
Issued 13 March 1991 Resolved
REPAIR SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Documentation
Issued 14 February 1990 Resolved
PROVIDE ON BOARD A ROUGH COPY OF AN OPERATING MANUAL MEETING APPLICABLE SECTIONS OF 46 CFR 109.121.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Documentation
Issued 14 February 1990 Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Documentation
Issued 14 February 1990 Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Documentation
Issued 14 February 1990 Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, FIRE CONTROL PLAN AND STRUCTURAL ANALYSIS ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990

Casualty record · 2

17 October 2011Routine · role: Involved in a Marine Casualty · activity 4179275
13 February 2012Routine · role: Involved in a Marine Casualty · activity 4250682
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.