Records in 2017. Most recent: inspection, 12 July 2017.
Documentation › Logs/Records › Oil Record Book
Issued 12 July 2017
Resolved
1710-An oil record book Part 1 shall be completed on each occassion for discharge overboard or disposal otherwise of bilge water which has accumulated in machinery spaces. The vessels Record Book Part 1 entries on 25MAY17 and 31MAY17 calculated throughput exceeds 5.0m3 per hour per IOPP supplement A Line 2.4. Vessel improperly identified equipment used to discharge overboard.MARPOL I/17.2.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2017
Resolution: Repaired / Rectified: Refer to "Statement of Fact" issued on Form: MAR 401 on 2017-05-10 which is attached to IOPP Supplement, it is specified that vessel is fitted with two OWSs. IOPP Supplement item 2.4 was referred in this statement and has been added.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 July 2017
No resolution recorded
0750-Fire Prevention - Doors fitted in boundary bulkheads or machinery spaces of Category A shall be reasonably gas tight and self closing. Category A-B Deck between engine room and steering gear room is not self closing.
14SOLAS II-2/9.4.2.1
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Cargo Stowage › General
Issued 12 July 2017
Resolved
1870-Special requirements - Cargo tanks shall be fitted with a visual and audible high level alarm which complies with 15.9.1 to 15.19.5 and which indicates when the liquid level in the cargo tank approaches the normal full condition slops tanks have no means of level indication.
MARPOL II/7
IBC 15.19.6
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 15 July 2017
Resolution: Discharge was from clean bilge system statement of fact added from class clears up misunderstanding.
Deck/Cargo › Cargo Stowage › General
Issued 12 July 2017
No resolution recorded
1870-Special Requirements - Cargo tanks shall be fitted with a visual and audible high level alarm. Visual high level alarm on deck is non operable.
MARPOL II/7
IBC 15.19.6
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 July 2017
Resolved
1730-An initial survey before the ship is put in service or before the certificate required under regulation 7 of this Annex is issued for the first time, which shall include a complete survey of its structure, equipment, systems, fittings, arrangements, and material. Vessel is equipped with with two OWSs in the Main Engine Room rated at 5 ppm. Vessel IOPP lists only one OWS.
MARPOL I/6.1.1
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 July 2017
Resolution: The slop tanks is only permitted for holding diluted washing water of liquid chemical cargo or dry-bulk hold washing water according to approved P&A Manual. In this case, slop tanks are not considered cargo tanks, the high level alarm is not required.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 July 2017
Resolved
0750-Fire prevention - Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least a 0 class divisions and be protected by self closing doors at all levels. Upper deck stairway door is not self closing.
SOLAS 14 II-2/9.2.3.4.1
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 July 2017
Resolved 12 July 2017
Resolution: Crew fixed the door while we were finishing the exam so that way it is self-closing.