MAURY USCG vessel records
← All vessels

OCEAN II

OCEAN II is a 1996 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2017, most recently in June 2026, along with 7 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 12 June 2026.

Built
1996
Last inspected
12 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ6071
1445333
Flag
UNITED STATES
Maury page id
psix-1445333

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Gross Ton
3 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

12 June 2026 Type not recorded
No type recorded · USCGC JOSEPH GERCZAK (WPC 1126) · USCG Oceania District (CGD-O) · Activity 8405719
18 May 2026 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8396062
22 April 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8430879
14 April 2025 Annual Inspection · Hull Examination
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8111871
1 May 2024 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7955220
18 April 2023 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7670629
14 June 2022 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7477388
11 June 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7227674
23 April 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7182083
7 December 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7107625
6 August 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7012411
26 June 2019 Deficiency Check · Drydock Exam · DAPI Audit · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6732541
6 August 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6502987
2 June 2017 DAPI Audit · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6163732

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 June 2022 Resolved
Vessel's blower to remove gas vapors is not installed correctly and is no capable of removing vapors. Provide ducting and prove proper operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2022
Resolution: Ducting is installed and vapor can safely be extracted from the space and vented to natural atmosphere.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 June 2022 Resolved
Vessel does not have a valve at its gas tank. Provide emergency cut off valve within 12" of the tank and properly marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 15 June 2022
Resolution: Cut Off Valve has be installed and is marked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 June 2022 Resolved
Vessels Aft hatch is missing its rubber seal and is not capable of sealing to the deck. Provide seal and prove hatch is watertight
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 24 June 2022
Resolution: Vessel has installed new freedom hatch assembly and is capable of preventing water from down flooding in the space.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 14 June 2022 Resolved
Vessels Navigational lights do not operate and is not properly mounted. Provide light capable of illuminating and prove they are properly installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 24 June 2022
Resolution: Vessel replaced Combo Nav light with new. Nav lights illuminate and burn brightly. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2022 Resolved
Vessel has dead end wires laying in the AFT bilge. Prove dead end wires are removed from vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 24 June 2022
Resolution: Dead wires that were to the bilge pump have been removed from the bilge. All sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 June 2019 Resolved
EPIRB disposable hydrostatic release must be replace two years after installation date. EPIRB hydrostatic release expired in June 2019. Provide a new hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 August 2019
Resolved 21 August 2019
Resolution: A new hydrostatic release was provided and installed prior to inspection completion.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 August 2018 Resolved
Spaces containing gasoline tanks are required to hae installed/fixed ventilation systems with a mechanical exhaust blower. The space containing the fuel tank does not have a ventilation system installed. Provide an approved ventilation system for this space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 21 August 2019
Resolution: A determination was made with the CID on these vessel the space is partially enclosed and does not require powered ventilation.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.