Records from 1997 to 2025. Most recent: inspection, 10 December 2025.
Documentation record
Registered dimensions (L × B × D)81.5 ft × 27.1 ft × 7.8 ft
Registered tonnagegross 226 / net 153
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAVO CORP · NEVILLE ISLAND PA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHARLESTON, WV
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it226 - Regulatory (Subpart C or D), Gross Ton
153 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 38
10 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8281610
9 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8249868
9 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8230168
31 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8072696
9 December 2024
TPO Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8045276
11 March 2024
Drydock Extension · MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7876896
19 July 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7746476
8 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7392799
19 August 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6787918
13 April 2019
Administrative Inspection · MTSA Verification · Initial Certification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6667467
19 February 2019
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6636751
3 November 2017
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6300131
13 December 2016
Administration · Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6073013
20 October 2014
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5009346
3 October 2014
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5014365
29 August 2014
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4990884
3 June 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4890511
2 April 2014
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4832563
17 October 2013
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4747666
16 September 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4858414
21 February 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4537401
4 July 2012
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4374168
21 June 2011
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4054256
1 November 2010
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3883016
18 May 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3741826
5 February 2010
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3676980
11 April 2008
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3186856
24 October 2005
MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2521888
19 June 2005
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2405288
27 August 2004
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2182397
14 March 2004
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2026755
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977907
15 August 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1664771
24 March 2000
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 64077
11 January 2000
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 45642
22 January 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 171102
5 April 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 72488
5 April 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 402873
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2019
Resolved
Electrical systems and equipment must minimize fire and shock hazards. Found multiple power strips chained together in the electrical room on the 2nd deck. Properly connect equipment to outlet without chaining.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 25 July 2019
Resolution: Removed the daisy chain
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2019
Resolved
At least two lifebuoys on a towing vessel greater than 26ft must be fitted with a floating electric light under approval series 161.010 or 160.110. The port side lifebuoy on the pilothouse was had the incorect battery installed in the floating light. Replace battery with one that is approved.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 19 August 2019
Resolution: correct battery installed
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 25 April 2019
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:
(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Oil soaked absorbent pads were seen in the bilges of the aft engine room. Replace pads with new ones.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 15 July 2019
Resolution: Corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 April 2019
Resolved
Each towing vessel must be equipped with at least two portable, battery-powered lights. One must be located in the pilothouse and the other at the access to the engine room. The light for the engine room had bad batteries. Replace the batteries.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 19 August 2019
Resolution: Replaced the batteries
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2019
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. On both main engines, the backside of the turbos were not lagged. Place lagging on turbos.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 19 August 2019
Resolution: lagging added