Records from 2021 to 2026. Most recent: inspection, 15 April 2026.
Inspection history · 12
15 April 2026
COC-CVE Quarterly
Type not classified · Sector New York · USCG Northeast District (CGD-NE) · Activity 8350308
25 March 2026
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8332070
15 October 2025
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8251991
16 April 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8111326
10 January 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8060880
16 October 2024
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8014562
9 April 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7891104
12 November 2023
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7821259
11 April 2023
PSC B · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7665735
30 October 2022
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7583679
26 August 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7552330
10 February 2021
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7138472
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 October 2025
Resolved
Within the perimeter of such stairway enclosures, only public toilets, locker of non-combustible material providing storage of non- hazardous safety equipment and open information counters are permitted. Inappropriate stowage was observed on Deck 5 in stairway 364J, and wheelchairs were being stowed in staiway 306J on deck 7.
74 SOLAS (20) II-2/13.3.2.3
Code 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 October 2025
Resolved 19 October 2025
Resolution: It has been confirmed that the Observed stowage spare glass on deck 5 at stairway 364J and wheelchairs stored at stairway 306J on deck 7 have been removed and replaced with the baggage embarkation area on deck 4 FZ 3.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 October 2025
Resolved
the following functional requirements shall be met escape routes shall be maintained in safe condition, clear of obstacles. Plants were observed in a category 2 space on deck 4.
74 SOLAS (20) II-2/13.1.2
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
Resolution: Plants were moved out of the space.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 October 2025
Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Fire door FSD 09 154 M did not fully latch when closed.
74 SOLAS (20) II-2/9.4.1.1.2
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 October 2025
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. Double leaf FSD 06 376 M closed incorrectly and too quickly.
74 SOLAS 9200 II-2/9.4.1.1.5.2
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 October 2024
Resolved
Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler of an approved type complying with the requirements of the Fire Safety Systems Code in all control stations, accommodation and service spaces, including corridors and stairways. PSCOs observed 4 ampules in locations (by FSD 07 034T, Mud Area 6174G, Steam Room 5172A, and by the Service Bar 6036P) that did not meet the requirements of the Fire Safety Systems Code because all five did not have the required fluid within the bulb, andone ampule in the Salt Room 5166A that did fully activate due to corrosion within the head.
74 SOLAS (2020) II-2/10.6.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 October 2024
Resolved
The construction of doors and door frames in 'A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO observed fire screen door 06 356 T in the theater not close and latch completely.
74 SOLAS (2020) II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 April 2024
Resolved
All powered-operated sliding watertight doors shall be
provided with means of indication which will show at all
remote operating positions whether the doors are open or
closed. PSCO identified the "door closed" LED lightbulb
indicator for watertight #2-1 inoperable in the remote control station on deck 4. 74SOLAS(20)II-2/13.6. Code 10C
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: A new LED lighbulb was installed, re-tested satisfactory.