← All vessels
SCARLET LADY
Passenger (Inspected) · Passenger Ship class · Built 2020s · USCG Southeast District (CGD-SE) · Other hulls named SCARLET LADY
SCARLET LADY is a 2020 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2018, most recently in April 2026, along with 12 deficiencies and 2 operational controls.
Records from 2018 to 2026. Most recent: inspection, 10 April 2026.
- Built
- 2020
- Last inspected
- 10 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9804801 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6DX2
1448364
Flag
BAHAMAS, THE
—
Maury page id
psix-1448364
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (2018–2026)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it74502 - Convention (Subpart B), Net Ton
108192 - Convention (Subpart B), Gross Ton
108192 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
10 April 2026
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8345264
11 January 2026
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8308706
31 October 2025
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8259121
14 December 2024
PSC A · COC-CVE Annual · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8045612
1 March 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7871674
1 September 2023
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7781534
26 July 2023
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7753468
16 July 2023
In-Service Inspection · Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7743494
7 June 2023
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7706489
8 March 2023
Administrative Inspection · PSC B · Deficiency Check · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7646061
14 February 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7636398
12 January 2023
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7620453
18 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579727
7 September 2022
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7553973
4 March 2022
Deficiency Check · Ballast Water Examination · COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7405673
11 January 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7378776
13 September 2021
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7309261
3 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935072
8 March 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6944728
7 March 2020
COC-CVE Initial · PSC C · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6921276
30 July 2018
COC-CVE Initial Prep · COC-CVE Initial
Administrative · Activities Europe · Activity 6537914
Deficiency record · 12
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 October 2025
Resolved
A fixed fire-extinguishing system, required by this chapter shal comply with the previsions of the FSS Code. PSCO's observed multiple empty high pressure water mist ampules within the Deck 3, Zone 5 uniform laundry room.
74SOLAS 20 II-2/10.4.1.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 October 2025
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposite closure. PSCO observed FSD 07 022 P was unable to self-close.
74 SOLAS 20 II-2/9.4.1.1.5.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 October 2025
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time for closure for hinges doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO obsureved FSD 04 093 M, located directly across from the ECR, closed in less time than 10 seconds.
74 SOLAS 20 II-2/9.4.1.1.5.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 December 2024
Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom.
PSCOs identified dry combustible trash being stored in combustible receptacles located in galley area on deck 7.
74 SOLAS (20) II-2/4.4.2
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 December 2024
Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14). Where the contents and use of a space are such that there is doubt as to it's classification for the purpose of this regulation, or where is is possible to assign tow or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Pool machinery space (cat 11) on deck 14 (14.252.j) had desk and work bench located in it, changing the space to a workshop (cat 13).
74 SOLAS 20 II-2/9.2.2.3.2.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 December 2024
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, opening shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are lifted.
Fire door 13.064.M on deck 13 did not release from the magnetic hook to close when activated locally from either sides of the door.
74 SOLAS 20 II-2/9.4.1.1.1
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 July 2023
Resolved
01- 02106- Ships built and maintained in conformity with the requirements of a classification society recognized by the administration may be considered to posses adequate strength. Vessel reported damage to starboard quarter after allision with pier. 17ac
ICLL CH1 REG1
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 March 2023
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO's observed crew member assigned as a stairway guide, crew stairway deck 15 aft, not familiar with his assigned emergency duties.
74 SOLAS 20 III/19.2.1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 January 2023
Resolved
The SCARLET LADY failed to submit an NOA prior to departure but at least 24 hours before arriving at the port or place of destination for a voyage less than 96 hours.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 March 2022
Resolved
Means of escape from control stations, accommodation spaces and service spaces. Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of force in the direction of escape flow. Primary means of escape from the BOSUN club had twist lock in the escape route, secondary means of escape from the aforementioned space had locked crash bar.
74 SOLAS 20 11-2/13.2.6.2
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 March 2022
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCOs found empty water mist ampule in sauna space, rendering it unavailable for immediate use.
74 SOLAS 20 II-2/14.2.1.2
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 September 2021
Resolved
Structural fire protection shall be kept in good order so as to ensure required preformance if a fire occures. Attending inspectors observed a space catagorized as "service" being utilized instead for "storage." Stored goods were moved. def rectified on the spot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.