NOVAYA ZEMLYA is a 2009 freight ship. The Coast Guard has recorded 1 inspection in 2017, along with 3 deficiencies.

Records in 2017. Most recent: inspection, 10 July 2017.

Built
2009
Last inspected
10 July 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 July 2017
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9549281
1450265
Flag
RUSSIA
Maury page id
psix-1450265

Documentation record

Tonnage as PSIX records it15868 - Convention (Subpart B), Gross Ton
7206 - Convention (Subpart B), Net Ton
23645 - Dead Weight, Metric Ton
34235 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

10 July 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6195555

Deficiency record · 3

Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 10 July 2017 Resolved
9900-Other(not clearly hazardous)-Operator of a vessel of a capacity of 250 or more barrels of oil shall provide transfer procedures that meet the requirements of this part and part 156 of the chapter. Vessel is unable to prove transfer procedures that meet the requirements of 33 CFR 155&156. Prior to bunkering in the United States provide transfer procedures meeting this requirement.33CFR 155.720
Action required: 703 - Prior to bunkering operations
Due 10 July 2017
Resolved 12 July 2017
Resolution: Recieved, reviewed and accepted proper documentation from master stating the deficiency has been rectified. Company provided proper transfer procedures.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 July 2017 Resolved
9900-Other(not clearly hazardous)-No person may use any equipment listed in paragraph C of this section for transfer operations unless the vessel tests and inspects the equipment in accordance with paragraph B,C and F of this section. Vessel could not provide proof of hydrostatic test in accordance with 156.170(c)(4) within the last year. Tests to be conducted prior to bunkering.33CFR 156.170(a) c
Action required: 703 - Prior to bunkering operations
Due 10 July 2017
Resolved 12 July 2017
Resolution: Recieved, reviewed and accepted proper documentation from master stating the deficiency has been rectified. Crew tested pipes to 1.5 X the MAWP.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 10 July 2017 Resolved
0720- Fire Fighting Equipment-Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO found the water supply valves on the hyper-mist system for the fuel oil purifier space closed. When valves were opened PSCO observed hyper-mist sprinkler heads in the fuel oil purifier space leaking water. SOLAS 74 (09 Cons) II-2/14.2.1.2 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 20 July 2017
Resolution: Received, reviewed, and accepted class report from Russian Maritime Register of Shipping stating automatic solenoid water supply valves were repaired and now operating properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.