MAURY USCG vessel records
← All vessels

MSC MANON

MSC MANON is a public freight. The Coast Guard has recorded 12 inspections since 2019, most recently in April 2023, along with 16 deficiencies and 2 operational controls.

Records from 2019 to 2023. Most recent: inspection, 24 April 2023.

Built
Not recorded
Last inspected
24 April 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 April 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2019–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9435820
1450308
Flag
PORTUGAL
Maury page id
psix-1450308

Documentation record

Tonnage as PSIX records it4900 - Simplified, Net Ton
9996 - Convention (Subpart B), Gross Ton
4900 - Convention (Subpart B), Net Ton
11775 - Dead Weight, Ton
9996 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

24 April 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7674169
21 December 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7611699
24 October 2022 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7578220
4 October 2022 Deficiency Check · PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7570664
16 September 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7560367
3 September 2022 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7547261
8 November 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7347184
19 April 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7179633
25 February 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7146139
29 July 2020 Ballast Water Examination · PSC B · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7018922
24 January 2019 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6614665
9 January 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6607673

Deficiency record · 16

01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 4 October 2022 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The objective nature of deficiencies 02, 03 and 04 demonstrate the vessel is not being maintained to international standards, bringing into question the validity of the Safety Management Certificate issued pursuant to the ISM Code. An external audit is required to be submitted prior to departure from port.
Action required: 30 - Ship detained
Due 4 October 2022
Resolved 10 October 2022
Resolution: PSC JAX received ISM External Audit report.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 October 2022 Resolved
Cargo ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the Code. Vessel does not have a rescue boat on board.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 4 October 2022
Resolved 10 October 2022
Resolution: Vessel installed a new rescue boat in kind, PSC JAX received class report attesting to crew competency and witnessing man over board drill.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 October 2022 Resolved
The quantity of water delivered shall be capable of supplying four nozzles of a size and at pressures as specified in regulation 10.2, capable of being trained on any part of the cargo space when empty. PSCOs observed emergency fire pump not able to provide adequate pressure for two hoses.
Action required: 30 - Ship detained
Due 4 October 2022
Resolved 10 October 2022
Resolution: PSCOs witnessed satisfactory test of emergency fire pump.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 October 2022 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in the manner having due regard to ensuring the reliability of fire fighting systems and appliances. Fixed fire fighting systems, portable fire extinguishers and fire detection system are past due on servicing dates.
Action required: 30 - Ship detained
Due 4 October 2022
Resolved 10 October 2022
Resolution: PSC JAX received new servicing reports regarding portable extinguishers, fixed CO2, and fixed fire detection systems.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 4 October 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCOs observed start button missing on sludge pump; No.2 ballast pump control panel hinge on cover was broken; General service salt water pump junction box was corroded and exposed to salt water, creating shock hazard.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2022
Resolved 10 October 2022
Resolution: PSC JAX received class report attesting to satisfactory repairs. PSCOs also verified while onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2022 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCOs observed unauthorized repairs to salt water piping in the form of clad welds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 21 December 2022
Resolution: Miami Arrivals received pictures of new piping as replacement
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 October 2022 Resolved
The following arrangements shall be tested in accordance with the Fire Test Procedures Code: Fire dampers, including their relevant means of operation. PSCOs observed seven (7) fire damper position indicators not working properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2022
Resolved 21 December 2022
Resolution: Miami Arrivals received photographs of the aforementioned fire dampers working properly
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 October 2022 Resolved
After any survey of the ship under Article 14, no change shall be made in the structure, equipment, arrangements, materials, or scantlings covered by the survey, without the sanction of the Administration. PSCOs discovered machinery space double bottom void cover was removed.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2022
Resolved 10 October 2022
Resolution: PSC JAX received class report attesting to proper closing of the hatch. PSCOs also verified while onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 4 October 2022 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board with due regard being paid to moving parts. PSCOs observed salt water pump shaft guard is missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2022
Resolved 10 October 2022
Resolution: PSC JAX received class report attesting to satisfactory repairs. PSCOs also verified while onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 October 2022 Resolved
Satisfactory means in the form of guardrails shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and other parts used in the necessary work of the ship. PSCOs observed wasted out handrails on the main cargo deck near embarkation area.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2022
Resolved 10 October 2022
Resolution: PSC JAX received class report attesting to satisfactory repairs. PSCOs also verified while onboard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 November 2021 Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship’s officers, showing clearly for each deck the control stations, the various fire sections enclosed by ‘‘A’’ class divisions. Several self closing doors in main stairwell did not close properly. 74 SOLAS (2004 Cons.) II-2/15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2021
Resolved 8 November 2021
Resolution: Doors fixed and verified while onboard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 November 2021 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight and seal closing. A-60 door leading from workshop to steering room has perforations allowing passage of smoke and flame. 74 SOLAS (2004 Cons.) II-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2021
Resolved 8 November 2021
Resolution: Door fixed and verified while onboard.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 November 2021 Resolved
An alarm system shall be provided indicating any fault requiring attention and shall: be capable of sounding an audible alarm in the main machinery control room. No audible alarm present in ECR or engine room workshop. 74 SOLAS (2004 Cons.) II-1/51.1.1
Condition: Unknown
Action required: 10 - Deficiency Rectified
Due 8 November 2021
Resolved 8 November 2021
Resolution: Alarms tested sat while onboard
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 November 2021 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight and seal closing. Door leading from engine room to steering room self closing device is detached. 74 SOLAS (2004 Cons.) II-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2021
Resolved 8 November 2021
Resolution: Door fixed and verified while onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 29 July 2020 Resolved
The purpose of the regulation is to prevent the ignition of combustible materials or flammable liquids. The following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. Pump packing was loose, resulting in a slow leak and oil-soaked lagging.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 July 2020
Resolved 29 July 2020
Resolution: Tightend packing on the sludge-oil pump. Replaced oil soaked lagging.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 9 January 2019 Resolved
...SHIPS ON INTERNATIONAL VOYAGESSHALL BE FITTED WITH A VOYAGE DATA RECORDER (VDR). PSCO OBSERVED INOPERABLE VDR INSTALLED ONBOARD. 74 SOLAS (14 CONS.) V/20.1.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2019
Resolved 24 January 2019
Resolution: Recieved technician report stating VDR to be fully operational.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.