Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it36272 - Convention (Subpart B), Gross Ton 63584 - Dead Weight, Metric Ton 75197 - Displacement, Metric Ton 21607 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018Resolved
13101 (Propulsion and Auxillary machinery) After any survey of the ship under regulations 7,8,9,or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items without the sanction of the of the Administration. PSCO Observed a F/O leak on the fuel pump of the No. 2 cylinder of the main engine which had been plugged with silicone putty while waiting for the shipyard to provide a technician to repair the leak. Provide clarification from Class on whether the temporary fix is adequate until the technician can serivce the vessel.
SOLAS 74(a) 2014 cons I/II(b) 17a
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2018
Resolved 21 July 2018
Resolution: PSC NOLA recieved a class report from ABS meeting the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018Resolved
13101 - (Propulsion and Aux machinery) - After any survey of the ship under regulations 7,8,9,or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items without the sanction of the Administratio. PSCO observed a F/O leak on the fuel pump of the No. 2 cylinder of the main engine which had been plugged with silicone putty while waiting for the shipyard to provide a technician to repair the leak. Provide clarification from Class on whether the temporary fix is adequate until the technician can service the vessel. SOLAS 74(a) 2014 cons. I/11(b) 17 a
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2018
Resolved 12 February 2019
Resolution: Received, reviewed and accepted proper documentation from master stating the main engine maker, Man Primeserve, attended the vessel and the deficiency was rectified.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.