KASSOS is a 2010 tank ship. The Coast Guard has recorded 7 inspections since 2017, most recently in July 2022, along with 2 deficiencies and 1 operational control.
Records from 2017 to 2022. Most recent: inspection, 2 July 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it4580 - Convention (Subpart B), Gross Ton 6256 - Dead Weight, Metric Ton 8899 - Displacement, Metric Ton 1967 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 7
2 July 2022Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7519624
21 March 2022COC-TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7415508
14 March 2021COC-TVE Renew
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7155805
12 March 2021Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7155239
10 October 2018Administrative Inspection · Deficiency Check
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 17 September 2018Resolved
06106 - Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters long. It must be located on the top of the flange. PSCO observed that vapor line on each manifold had no visible stud. Correct prior to conducting cargo with vapor operations. 46 CFR 39.2001)j) a,c
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 October 2018
Resolution: PSC HOU received Class DNV GL report attesting to satisfactory installation of permanent studs on all vapor manifolds.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 17 September 2018Resolved
06160 - Each vapor hose must be labeled with the word "VAPOR" painted in black letters at least 50.8 millimeters (2 inch) in height. PSCO observed no labeling of the vapor lines on either manifold. Correct prior to conducting cargo with vapor operations. 46 CFR 39.2001(h)(2) a,c
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 October 2018
Resolution: PSC HOU received Class DNV GL report attesting to satisfactory addition of "VAPOUR" in black lettering on all vapor manifolds.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.