Records from 1993 to 2026. Most recent: inspection, 23 January 2026.
Documentation record
Registered dimensions (L × B × D)54.0 ft × 22.1 ft × 7.1 ft
Registered tonnagegross 64 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAIN IRON WORKS INC · BAYOU BLUE, LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORTH KINGSTOWN, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Gross Ton
43 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
23 January 2026
Deficiency Check · Administrative Inspection · Vessel Attendance · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8300785
7 November 2024
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8031887
14 May 2024
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7870430
18 April 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7654950
20 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7444438
20 January 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7382887
17 December 2021
Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7380053
2 December 2021
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7361788
21 September 2021
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7306062
9 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7165565
25 June 2020
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7001933
3 January 2020
DAPI Audit · Initial Certification · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6882100
27 August 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6524330
19 June 2012
DAPI Audit · Industry Initiated Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4348794
17 February 2012
Administration
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4246280
18 January 2011
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3929295
15 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2427900
8 October 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 213948
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 5 February 2026
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. The line throwing appliance must have an auxiliary line that:(i) Is at least 450 meters (1,500 feet) long;(ii) Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force); and(iii) Is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light. Provide the remaining 2 required line throwing devices and the auxiliary line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2026
Resolved 31 March 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2026
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Remove wingnuts from battery connections and install proper fasteners.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2026
Resolved 17 February 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2026
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Provide a cover for the port and stbd terminal blocks above the MDEs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2026
Resolved 31 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The port generator failed to start due to a suspected faulty starter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2026
Resolved 31 March 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2026
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. A fire hazard exists where the berthing hatch door obstructs the heater, provide an alternate arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2026
Resolved 31 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2022
Resolved
Retroreflective tape on starboard ring buoy showing signs of wear. Replace retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2022
Resolution: Tape replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2022
Resolved
Loose wiring found underneath nav console, remove or properly secure wiring.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2022
Resolution: Wiring removed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 May 2022
Resolved
Light stands are painted glossy black. Need to be matt black background to reduce glare/reflection of running lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2022
Resolution: Light stands painted matt black
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 20 May 2022
Resolved
Potable water vent missing insect screen. Install insect screen on vent.
21 CFR 1250
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2022
Resolution: Screens installed on vents
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 September 2021
Resolved
Crop and re-new damaged hull plating and crushed vertical framing on the aft port and stbd side of the lazarette.
Complete Repairs NLT 31DEC2021.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 December 2021
Resolved 18 February 2022
Resolution: Repairs completed
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 September 2021
Resolved
Crop and re-new the bent lazarette stbd aft longitudinal frame. Complete Repairs NLT 31DEC2021.
Action required: 705 - Other - as specified
Due 31 December 2021
Resolved 18 February 2022
Resolution: Repairs completed
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 21 September 2021
Resolved
Crop and renew the aft deck / lazarette overhead that is wasted through and has been doubled.
Complete Repairs NLT 31DEC2021.
Action required: 705 - Other - as specified
Due 31 December 2021
Resolved 18 February 2022
Resolution: Repairs completed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2021
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Fuel tank sight glasses made of plastic. Install self-closing valves on sight glass.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2021
Resolved 3 May 2021
Resolution: Self-closing valves installed. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: MMSI from expired FCC License, Call Sign from expired FCC License, and
Vsl is broadcasting Beam > than LOA.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 September 2018
Resolved 11 October 2018
Resolution: Vessel is now broadcasting accurate data.