Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it25622 - Convention (Subpart B), Gross Ton 13063 - Convention (Subpart B), Net Ton 48869 - Displacement, Metric Ton 38801 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2024Resolved
Electrical installation shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed electrical tape on exposed wires at cable gland receptacle for the freefall lifeboat and stbd side accomodation ladder.
74 SOLAS (20) 11-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2024
Resolved 11 November 2024
Resolution: Submitted Class survey report and pictures showing deficiency has been rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 November 2024Resolved
Where exposed to sunlight, lifebuoy grablines shall be resistant to deterioration and form four equal loops. PSCO observed incorrect grabline and installation.
74 SOLAS (20) III/1.5 LSA 1/1.2.2.5
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 November 2024
Resolved 7 November 2024
Resolution: Grabline was replaced and installed properly.
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must remove fouling organisms form the vessel's hull on a regular basis. PSCO observed excessive growth of fouling organisms on starboard side of the vessel's hull. Provide documentation from the Administration or the certificate issuing authority attesting the removal of fouling organisms.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2022
Resolution: PSCO's observed cleaned hull during PSC B exam.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.