MAURY USCG vessel records
← All vessels

ATLANTIC ASPHALT

ATLANTIC ASPHALT is a 2017 tank ship. The Coast Guard has recorded 20 inspections since 2017, most recently in June 2026, along with 9 deficiencies and 1 operational control.

Records from 2017 to 2026. Most recent: inspection, 22 June 2026.

Built
2017
Last inspected
22 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 June 2026
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9798428
1455394
Flag
MARSHALL ISLANDS
Maury page id
psix-1455394

Documentation record

Tonnage as PSIX records it17763 - Dead Weight, Metric Ton
4345 - Convention (Subpart B), Net Ton
25603 - Displacement, Metric Ton
14485 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

22 June 2026 Administrative Inspection · PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8406921
13 February 2025 PSC B · COC-TVE Annual
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8077767
31 August 2024 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7992952
22 July 2024 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7964400
14 July 2024 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7958003
11 July 2024 In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7955674
26 June 2024 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7942853
14 February 2024 COC-TVE Renew · Deficiency Check · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7862181
26 July 2023 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7753448
16 January 2023 COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7619948
19 January 2022 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7379756
4 November 2021 Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7345454
9 January 2021 PSC B · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7118936
18 December 2019 ISPS III Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6875903
18 December 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6876290
15 April 2019 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6660411
23 June 2018 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6453108
31 March 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6382465
26 March 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6378663
17 December 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6323447

Deficiency record · 9

09 - Working and Living Conditions › 092 - Working Conditions › Entry dangerous spaces
Issued 22 June 2026 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. PSCO observed broken/INOP safety interlock solenoid for pump room lighting with no certified safe replacement onboard. 74 SOLAS (20) II-I/ 45.11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2026
Resolved 18 August 2026
Resolution: PSC NOLA received a class report/technician’s report/proper documentation from issuing entity satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 February 2025 Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes. PSCO observed the rescue boat was unable to start in an adequate amount of time. 74 SOLAS (20) III/14.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 February 2025
Resolved 13 February 2025
Resolution: Crew was able to demonstrate successful operation of engine prior to completion of exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2024 Resolved
Vessel experienced loss of communication between the bridge and main engine. 74 solas(20)I/IIa
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2024
Resolved 16 September 2024
Resolution: Recieved Tect and Class Report staing the repairs have been completed
10 - Safety of Navigation › N/A - No Subsystem › Use of the automatic pilot
Issued 11 July 2024 Resolved
ALL SHIPS OF 10,000 GROSS TONNAGE AND UPWARDS SHALL, IN ADDITION TO MEETING THE REQUIREMENTS OF PARAGRAPH 2.7, WITH THE EXCEPTION OF PARAGRAPH 2.7.2, HAVE A HEADING OR TRACK CONTROL SYSTEM, OR OTHER MEANS, TO AUTOMATICALLY CONTROL AND KEEP TO A HEADING AND/OR STRAIGHT TRACK. PSCO WAS NOTIFIED BY VESSEL'S MASTER THAT WHILE INBOUND TO BALTIMORE, MD THE HEADING CONTROL SYSTEM, "AUTOPILOT", IS MALFUNCTIONING. REPAIR HEADING CONTROL SYSTEM TO FULLY SAFE OPERATIONG CONDITION PRIOR TO DEPARTURE.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2024
Resolved 14 July 2024
Resolution: Received class/tech report from BV clearing deficiencies issued 11JUL2024 by MSU Lewes as documented in MISLE activity # 7955674
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 26 June 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IS ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. UNSTABLE ECDIS SIGNAL FROM AUTOPILOT TO VDR. 74SOLAS(20) CH. 1 REG 11(A)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2024
Resolved 22 July 2024
Resolution: Received Class Report from [name withheld] attesting to the repairs of the VDR.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 14 February 2024 Resolved
Such certificate shall be issued or endorsed as appropriate either by the administration or by any persons or organization duly authorized by it. In every case the administration assumes full responsibility for the certificate. PSCO observed that the international oil pollution prevention certificate supplement did not mention other acceptable means in 3.2.3. MARPOL (2022 Cons. Ed.)I/7.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 28 March 2024
Resolution: Received email from Class BV with screenshot of revised IOPP supplement that had been revised.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 14 February 2024 Resolved
The high-level alarm required by paragraph (a) of this section must- (1) activate an alarm once the cargo level reaches 95 percent of the tank capacity or higher, but before the tank overfill alarm. Crew of vessel was unable to demonstrate proper operation of high level alarm for the #1 starboard cargo oil tank. 46CFR39.2007(c)(1)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2024
Resolved 31 March 2024
Resolution: Received class report attesting to repair and satisfactory testing of high level alarm.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 4 November 2021 Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2021
Resolution: BWTS is operational and verified by Class.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 December 2019 Resolved
Provisions shall be made to guard against liquid rising into the venting system. This shall be accomplished by high level alarms and overfill control systems. Vessels high level alarm on 3 port tank is inoperative. 74SOLAS(14) II-2/11.6.3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 January 2020
Resolved 21 January 2020
Resolution: Recieved class report attsting to the repair.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.