MAURY USCG vessel records
← All vessels

OCEAN BANQUET

OCEAN BANQUET is a 2017 freight ship. The Coast Guard has recorded 5 inspections since 2018, most recently in April 2026, along with 3 deficiencies and 1 operational control.

Records from 2018 to 2026. Most recent: inspection, 14 April 2026.

Built
2017
Last inspected
14 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9740108
1455475
Flag
HONG KONG
Maury page id
psix-1455475

Documentation record

Tonnage as PSIX records it36415 - Convention (Subpart B), Gross Ton
65173 - Dead Weight, Metric Ton
76958 - Displacement, Metric Ton
21579 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

14 April 2026 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8334100
2 December 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7603245
25 May 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7459346
27 October 2021 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7331036
4 April 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385011

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 April 2026 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a leak on the M/E lube oil purifier No. 2. 74 SOLAS (Cons.) II-2/4.1.1 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 April 2026
Resolved 16 April 2026
Resolution: Sec Nola PSC received report from Lloyd's Register satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 April 2026 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed inappropriate locking mechanism for escape door out of the steering gear room. 74 SOLAS (Cons.) II-2/13.1.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2026
Resolved 16 April 2026
Resolution: Sec Nola PSC received report from Lloyd's Register satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 April 2026 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the orginization. PSCO observed a fire extinguisher in CO2 room missing 2 monthly verifications since January. 74 SOLAS (Cons.)II-2/14.2.2.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 April 2026
Resolution: Vessel's crew rectified on the spot.

Ownership record