Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)38.8 ft × 15.0 ft × 6.3 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE GROUP BOAT WORKS · NATIONAL CITY, CA, UNITED STATES · built 2017
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton 19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
9 July 2026Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8433594
10 July 2025Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8180265
31 July 2024Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7971713
10 July 2024COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7942902
5 July 2023Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7733572
22 October 2022Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7586868
26 July 2022Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7517167
5 August 2021Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7278220
6 October 2020Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7072288
23 August 2019Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6792479
23 April 2019DAPI Audit · Deficiency Check · Initial Certification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6673788
9 November 2017DAPI Audit · Uninspected Other
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6317757
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2026Resolved
Portable fire pump must be self-priming and power-driven, with a minimum capacity of at least 300 LPM (80 gpm) at a discharge gauge pressure of not less than 414 kPa (60 psi), measured at the pump discharge. Pump was working with pressure, but MI was unbale to prove proper pressure on pump due to broken gauge. Replace gauge to prove pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2026
Resolved 10 July 2026
Resolution: Received video of portable fire pump operating at the correct pressure. All SAT.
Watertight doors must be marked on both sides "WATERTIGHT DOOR-KEEP CLOSED" No markings were found on either side of the watertight door. 46 CFR 144.160
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 July 2025
Resolution: Rcvd pictures of the watertight door markings.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 10 July 2025Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47CFR part 80. Vessels radio did not have the position programmed into the radio.
46CFR140.715
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 July 2025
Resolution: Recieved pic of proper installation.
ALL VESSELS MUST UNDERGO AN ANNUAL INSPECTION WITHIN 3 MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE. VSL IS OVERDUE FOR IT'S REQUIRED ANNUAL AS OF 16 OCT 2022.
VSL IS RESTRICTED FROM PUSHING, PULLING OR HAULING ALONGSIDE TYPE OPERATIONS UNTIL IT'S REQUIRED INSPECTION IS COMPLETED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2022
Resolution: conducted annual
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 October 2020Resolved
PROVIDE USCG WITH FCC SAFETY RADIO CERTIFICATE ISSUED TO VESSEL.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2020
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2020Resolved
INSTALL CHAFING GEAR FOR STEERING RAM HYDRAULIC HOSES.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2020
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 October 2020Resolved
ENSURE LAZERETTE/ER BULKHEAD PENETRATIONS ARE SEALED FOR WATERTIGHT AND FIRE BOUNDRY INTEGRITY.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2020
Resolution: Corrected
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2019Resolved
Begin testing and records of items listed in Table 143.245(b).
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 August 2019
Resolved 2 August 2019
Resolution: PMS reviewed. Testing scheduled appropriately.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 November 2017Resolved
Provide light list of current operating area.
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 2 August 2019
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 November 2017Resolved
Provide tide tables of current operating area.
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 2 August 2019
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 November 2017Resolved
Provide Coast Pilot of current operating area.
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 2 August 2019
Navigation › Piloting/Steering › Marine Charts
Issued 9 November 2017Resolved
Provide chart of current operating area.
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 2 August 2019
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 9 November 2017Resolved
Provide fire detection. Control panel, audible & visual alarms at both operating stations, two power sources, labels for switches and indicator lights identifying their functions and maintained IAW manufacturer's manual. 46CFR27.203
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 2 August 2019
Resolution: Alarms Provided
Fire Fighting › Fire Pumps › Power Source
Issued 9 November 2017Resolved
Make fire pump capable of being energized at the pump. 46CFR27.301
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 2 August 2019
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 November 2017Resolved
Provide proof drug testing program with documentation.
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 2 August 2019
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.