Records from 1986 to 2023. Most recent: inspection, 17 August 2023.
Documentation record
Registered dimensions (L × B × D)38.0 ft × 13.2 ft × 6.2 ft
Registered tonnagegross 17 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRUNO & STILLMAN INC · NEWINGTON, NH, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLYNN HAVEN, FL
Trade endorsementsFishery
DocumentationValid · issued 2 June 2026 · expires 30 June 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
17 August 2023
Type not recorded
No type recorded · USCGC EDGAR CULBERTSON (WPC-1137) · USCG Heartland District (CGD-H) · Activity 7784560
25 November 2017
Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 6315908
7 September 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5996322
6 January 2011
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3922461
9 February 2005
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2294358
29 February 2004
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2015071
27 February 2004
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2014863
23 April 2003
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1779900
2 July 2001
Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 695244
29 June 2001
Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 1521524
4 January 2001
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 1521238
28 January 1999
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 1511382
8 September 1997
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 786479
30 May 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465872
1 June 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1420979
26 April 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1463889
5 August 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 863303
2 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 851977
12 October 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1148883
15 July 1993
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1157360
6 July 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847926
8 January 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 828215
3 September 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 942784
28 May 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 961546
8 May 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1264618
30 May 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 937595
14 June 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 915057
7 November 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 907369
1 June 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1196483
7 June 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 891717
7 January 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1018410
15 October 1987
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1020076
11 September 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1319479
10 June 1987
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1031176
18 June 1986
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1303116
Electrical
Issued 1 June 1995
Resolved
INSTALL THE FOLLOWING ONTO THE NEWLY REPLACED SHIPS SVC GENERATOR:_x001C_ A. ALL FLEXABLE FUEL HOSES SHALL HAVE FACTORY TYPE PRESSED ON FITTINGS._x001C_ B. INSTALL PLATE SHOWING AMBIENT OPERATING TEMP OF GENERATOR._x001C_ C. REINSTALL SHUT OFF SWITCH CONNECTION VESSEL'S FIXED FIRE SYS TO GEN.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Navigation
Issued 15 July 1993
Resolved
PROVE OPERATION OF INSTALLED AM USB RADIO TELEPHONE.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Fire Fighting
Issued 28 May 1992
Resolved
PROVIDE DOCUMENTATION THAT ALL PORTABLE AND FIXED FIRE EXTINGUISHERS HAVE BEEN SERVICED WITHIN THE PAST 12 MONTHS.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Construction/Loadline
Issued 28 May 1992
Resolved
RENEW DOGGING MECHANISM FOR FORWARD DECK HATCH.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Engineering
Issued 28 May 1992
Resolved
PROVIDE A SUITABLE ALARM TO DETECT LOSS OF FLOW TO EXHAUST COOLING WATER SYSTEM. SUCH ALARM SHALL BE AUDIBLE OR VISUAL AT THE ENGINE OPERATING STATION.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Electrical
Issued 28 May 1992
Resolved
PROVIDE EVIDENCE THAT GENERATOR WINDINGS INSULATION IS DESIGNED FOR AN AMBIENT TEMPERATURE OF 50 DEGREES c (122 DEGREES f).
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Navigation
Issued 28 May 1992
Resolved
PROVE OPERATION OF PORT RUNNING LIGHT.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Accommodation/Occupational Safety
Issued 11 September 1987
Resolved
INSTALL RIGID PERMANENT FIRE PROOF VENTILATION DUCT TO ENGINE SPACE BILGE.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Accommodation/Occupational Safety
Issued 11 September 1987
Resolved
PROVIDE SUITABLE VENT PLUGS OR COVERS FOR BOTH E.R. VENTS.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Fire Fighting
Issued 11 September 1987
Resolved
PROVIDE SIGN OR PLACARD AT CO2 CONTROLS STATING " CLOSE VENTS PRIOR TO ACTIVATING SYSTEM"
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Fire Fighting
Issued 11 September 1987
Resolved
PROVE PROPER OPS OF CO2 AUTO FIRE DETECTION ALARM SYSTEM.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Construction/Loadline
Issued 11 September 1987
Resolved
ENCLOSE & MAKE GAS TIGHT TRANSVERSE BULKHEAD AFT OF FUEL TANK SPACE.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Construction/Loadline
Issued 11 September 1987
Resolved
MAKE FWD ENGINE ROOM BULKHEAD GAS TIGHT.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987