Records from 1999 to 2022. Most recent: inspection, 18 April 2022.
Documentation record
Registered dimensions (L × B × D)46.1 ft × 18.0 ft × 6.7 ft
Registered tonnagegross 54 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTUCKER MARINE INC · CINCINNATI, OH, UNITED STATES · built 1976
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLACON, IL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Gross Ton
36 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
18 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7433080
30 October 2019
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6848685
16 October 2014
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5007056
25 October 2013
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4741217
6 September 2013
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4710082
20 February 2013
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4536520
20 September 2012
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4446117
16 September 2010
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3851283
5 August 2010
Industry Initiated Exam · MARPOL
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3819203
20 August 2009
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3572642
27 May 2009
Administration · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3488386
8 December 2008
Deficiency Check · Uninspected Other · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3382708
1 December 2008
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3372274
25 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2940944
26 April 2007
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2917183
15 February 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2585570
9 November 2005
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2531506
21 September 2005
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2500064
14 September 2005
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2492360
17 April 2003
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1775417
24 April 2002
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1609132
21 March 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1599824
4 October 2000
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1459636
1 April 1999
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 785806
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 December 2008
Resolved
Prior to getting U/W, prove proper operation of the emergency fuel valves shut-off system. During testing the pull cable parted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 January 2009
Resolved 29 January 2009
Resolution: Added to inspection note since the vessel is laid-up pending sale.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 December 2008
Resolved
Prior to getting U/W, ensure the fwd engineroom bulkhead, the forward fuel tank void bulkhead and the ladder slope sheet IWO the main deck are watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 January 2009
Resolved 29 January 2009
Resolution: Added to inspection note since the vessel is laid-up pending sale.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 April 2007
Resolved
Fire detection system not working under battery power per 46 CFR 27.203
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Fire detection system now working.
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 April 2007
Resolved
Operating instructions required at remote fuel oil shutoff handle per 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Remote Fuel shutoff now labeled with operating instructions.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 April 2007
Resolved
Guards required over shaft behind port and starboard engines per good marine practice
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Guards now in place.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 26 April 2007
Resolved
Electrical boxes need to be properly labeled per good marine practice
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 25 May 2007
Resolution: Electrical boxes now labeled.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 9 November 2005
Resolved
Provide proof that fire detection system is certified by a licensed professional engineer or classification society as required under 46 CFR 27.203 See 46 CFR 27.203 (g) for requirements
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2005
Resolved 3 February 2006
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 9 November 2005
Resolved
Fire detection system power panel needs battery backups as reequired under 46 CFR 27.210 (e)
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2005
Resolved 3 February 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 13 September 2005
Resolved
Fire Pump as required under 46 CFR 27.301 not on board
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2005
Resolution: Fire pump now on vessel
Communications › Alarms/Indicators › General Alarm
Issued 13 September 2005
Resolved
General Alarm and flashing red light not on board as required under 46 CFR 27.201
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2005
Resolution: General Alarm and flashing red light installed as required under 46 CFR 27.201
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 September 2005
Resolved
Magnetic compass on board not illuminated as required under 33 CFR 164.72 (a)(4)
Condition: Unknown
Due 12 October 2005
Resolved 8 November 2005
Resolution: Magnetic compass installed and illuminated as required under 33 CFR 164.72 (a)(4)
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 13 September 2005
Resolved
Local notice to mariners not on board as required under 33 CFR 164.72 (b)(2)
Condition: Unknown
Due 12 October 2005
Resolved 8 November 2005
Resolution: Company will obtain Local notice to mariners from neighbooring company and have onboard as required under 33 CFR 164.72 (b)(2)
Personnel › Training › Fire Fighting Basic
Issued 13 September 2005
Resolved
No monthly records or evidence of fire fighting training for crew being conducted as required under 46 CFR 27.209
Condition: Unknown
Due 12 October 2005
Resolved 8 November 2005
Resolution: Company has training tapes and starting a training program and will log monthly training and drills as required under 46 CFR 27.209
Documentation › Certificates/Documents
Issued 1 April 2002
Resolved
CERTIFICATE OF DOCUMENTATION EXPIRED 46 CFR 67.7 LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2002
Resolution: COD VALID
Fire Fighting › Remote Fuel Shutoff
Issued 1 April 2002
Resolved
NO REMOTE FUEL OIL SHUTOFF 46 CFR 27.230
Due 10 April 2002
Resolved 10 April 2002
Resolution: REMOTE FUEL OIL SHUTOFF INSTALLED
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 April 2002
Resolved
PFD'S ON BOARD NOT CG APPROVED (TWO REQUIRED) 46 CFR 25.25-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2002
Resolution: PFD''S NOW ON BOARD
Lifesaving
Issued 4 October 2000
Resolved
Unknown Component - Unknown Cause/Condition (46C.F.R.25.25-5(d))
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000
Fire Fighting
Issued 4 October 2000
Resolved
FIRE EXTINGUISHERS INSPECTION DATE LAPSED.
Condition: Unknown
Due 4 October 2000
Resolved 4 October 2000