Records from 1994 to 2025. Most recent: inspection, 14 November 2025.
Documentation record
Registered dimensions (L × B × D)118.7 ft × 34.0 ft × 14.6 ft
Registered tonnagegross 198 / net 134
ITC dimensions (L × B × D)120.2 ft × 34.0 ft × 16.0 ft
ITC tonnagegross 424 / net 127
BuilderMCDERMOTT SHIPYARDS · PORT OF NEW IBERIA, LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKETCHIKAN, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 October 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it198 - Regulatory (Subpart C or D), Gross Ton
424 - Convention (Subpart B), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
127 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 33
14 November 2025
Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8268124
18 June 2025
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8162293
11 February 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8078200
6 January 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8058807
20 May 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7916437
13 September 2023
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7799614
5 April 2022
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7425284
3 April 2020
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6939226
8 January 2020
TPO Audit
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6888342
12 November 2019
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6859537
29 October 2019
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6844522
17 July 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6754652
22 April 2019
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6681332
19 April 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6397451
5 December 2014
Administration
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5035056
7 May 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4864401
30 October 2013
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4745816
15 June 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3768798
1 May 2010
Type not recorded
No type recorded · Station Valdez · USCG Arctic District (CGD-A) · Activity 3728416
28 December 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3658644
19 November 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3636755
20 October 2009
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3619426
13 February 2009
Uninspected Other
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3419106
27 October 2006
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2809388
7 December 2004
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2255726
23 July 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2155300
20 December 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 84815
6 March 1998
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 70990
21 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 63666
4 April 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 118643
7 August 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 5177
17 July 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 188082
13 March 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 18661
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 27 September 2023
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, other openings into such spaces. Ventilation dampers did not fully secure and required hand tools to operate. Repair dampers to operational condition.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 21 March 2024
Resolution: Ventilation dampers were satisfactorily rebuilt.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 September 2023
Resolved
Must carry portable fire extinguishers IAW table 142.230(b), and One 40–B extinguisher for each 1,000 brake horsepower of the main engines. Identified portable extinguishers in machinery space were not all 40-B. Install TWO more 40-B portable extinguishers in machinery space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 21 March 2024
Resolution: Verified 2 additional extinguishers were installed in machinery space.
12 - Dangerous Goods › N/A - No Subsystem › Special requirement
Issued 27 September 2023
Resolved
Paints, flammable, and combustible products must be stored in a designated storage cabinet when not in use. A 40–B portable fire extinguisher must be located near the storage room or cabinet.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 21 March 2024
Resolution: Verified satisfactory portable extinguisher installed by paint locker.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 September 2023
Resolved
The Master must ensure all hatches, doors, and other openings designed to be watertight function properly. Watertight doors did not properly secure close and gaskets were found unsatisfactory. Repair gaskets and dogs on watertight doors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 21 March 2024
Resolution: ABS completed load line survey 13FEB24 and verified satisfactory operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 September 2023
Resolved
At least two lifebuoys must be fitted with a floating electric water light. The water light must be attached by the lanyard with a corrosion-resistant clip to allow the water light to be quickly disconnected from the lifebuoy. The clip must have a strength of (50 pounds). Each lifebuoy with a floating electric water light must have a lanyard of at least (3-6 feet), securing the water light around the body of the lifebuoy. Install clips and attach lanyards to body of lifebuoys. Mark name of vessel in block capital letters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 21 March 2024
Resolution: Corrections to lifebuoys were installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 September 2023
Resolved
Fixed fire-extinguishing systems must be approved by the Commandant (CG–ENG). Halon systems that are nolonger approved by Commandant will have to demonstrate that the system was approved at the time of installation. Provide P.E. approval drawing of the combination Halon CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 21 March 2024
Resolution: Received Halon system documentation. Accepted system as existing equipment IAW 46CFR142.215(d).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 3 February 2020
Resolved
The purpose of a TSMS is to establish policies, procedures, and required documentation to ensure the owner or managing operator meets its established goals while ensuring continuous compliance with all regulatory requirements. The TSMS must contain a method to ensure all levels of the organization are working within the framework. An external vessel audit conducted on 08JAN20 identified 9 non conformities with the SMS as noted on ABS report 4080173. Conduct an audit of the company safety management system related to the non conformities identified in ABS report 4080173 including but not limited to the conduct of internal audits, the roles and responsibilities of the DPA and other management personnel, accident reporting procedures, management of change process and overall records management.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2020
Resolved 17 June 2020
Resolution: Received final audit report from ABS attesting to correction of all non-conformities (see MISLE# 6917069, Management System Oversight activity originated by MSD Ketchikan).
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 20 November 2019
Resolved
The management must demonstrate that they implemented the policies and procedures as contained in the TSMS and the entire organization is adhering to their safety management program. The TSMS Maintenance Procedures identify the main propulsion, electrical power generating system, and fuel systems as critical systems and notes all found deficiencies in critical systems shall be resolved with priority and made safe by the vessel master or shore side support. If the deficiency cannot be resolved with priority, the Management of Change process shall be utilized which includes an inspection by the asset integrity team. As noted in deficiencies 2 and 3, there is an exhaust leak in the engine room and a hole in the engine room fuel day tank. The vessel master reported these items during nearly every Weekly Vessel Condition Report beginning in August 2018 as well as the monthly vessel safety and maintenance inspection report. There is no objective evidence proper action was taken by the company when the deficiency reports were received. Conduct an external audit of the vessel towing safety management system to include the TSMS Maintenance Procedures section. 46CFR 138.210(b).
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Due 20 December 2019
Resolved 8 January 2020
Resolution: External Audit conducted by TPO, findings identified. Exhaust system and fuel oil leak have been replaced/repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 November 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide for the safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. There is a significant exhaust leak in the machinery space. 6 CFR 143.205
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 20 December 2019
Resolved 8 January 2020
Resolution: Exhaust system and fuel oil leak have been replaced/repaired.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 November 2019
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. There is an approximately 1 inch diameter hole in the fuel day tank allowing fuel and flammable vapors to leak into the machinery space. 46 CFR 143.220
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 20 December 2019
Resolved 8 January 2020
Resolution: Exhaust system and fuel oil leak have been replaced/repaired.