Records from 1997 to 2025. Most recent: inspection, 28 October 2025.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 20.5 ft × 7.0 ft
Registered tonnagegross 69 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO, INC · GUILD TN, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDUBUQUE, IA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
28 October 2025
Administrative Inspection · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8260125
6 October 2025
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8255632
23 July 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7965140
24 October 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7814053
8 August 2022
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7528345
5 May 2022
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7459031
14 June 2021
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7226139
9 September 2020
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7007133
18 November 2019
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6857742
15 November 2019
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6868163
26 November 2012
Administration
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4490349
9 October 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 294890
5 October 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 154676
5 October 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 168957
31 August 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 281766
22 April 1999
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 428023
8 January 1998
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 760148
2 October 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 209496
2 October 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 409362
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 January 2026
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202. The vessel's COI has expired as of 09SEP2025. Complete renewal inspection prior to engaging in or intending to engage in the service of pulling, pushing, or hauling alongside, or any combination of pulling, pushing, or hauling alongside. 46 CFR 136.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2026
Resolved 23 April 2026
Resolution: Renewal inspection completed 23APR2026, COI routed for signature.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 October 2025
Resolved
An internal structural examination required by this part may be conducted while the vessel is afloat or while it is out of the water. It consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking...Identified wastage in forward void, centerline on overhead below "H" bar. Identify extent of wastage, crop and renew to good metal. 46 CFR 137.330(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2025
Resolved 23 April 2026
Resolution: Wasted steel was cropped and renewed with an approximate 3 ft x 4 ft insert plate. The H-bit was reattached, and non-destructive testing (liquid dye penetrant) was performed with satisfactory results.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 August 2022
Resolved
(a) Essential systems or equipment must be regularly tested and examined. (b) Each towing vessel must perform the applicable test in Table 143.245(b). Vessel could not provide testing or documentation of testing of machinery alarm set points as prescribed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2022
Resolved 16 December 2022
Resolution: volvo conducted test, all sat
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 August 2022
Resolved
For closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Vessel does not have prescribed means of closing for both engine room ventilators
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2022
Resolved 23 September 2022
Resolution: cover made to cover ventilation
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2020
Resolved
Provide operational water light for port side ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 16 September 2020
Resolution: Vessel rep sent video of operational water light.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 September 2020
Resolved
Provide approved and operational smoke detector on the bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 9 September 2020
Resolution: Replaced smoke detector before end of inspection.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 9 September 2020
Resolved
Label fuel shut off valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 9 September 2020
Resolution: Labeled prior to end of inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 September 2020
Resolved
Prove 120 minute operation of emergency lighting/ batteries prior to recertification/ inspection year 2025.
Action required: 705 - Other - as specified
Resolved 23 April 2026
Resolution: verified vessel had installed Non-electric, phosphorescent adhesive lighting strips installed along escape routes.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 November 2019
Resolved
Any vessel of at least five net tons wholly owned by a U.S citizen engaged in trade is required to have a Certificate of Documentation.
Vessel and company cannot prove vessel has a valid Certificate of Documentation.
Action required: 30 - Ship detained
Resolved 13 May 2020
Resolution: COD onboard.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 November 2019
Resolved
Prove proper operation of fire pump and fire hose.
Action required: 30 - Ship detained
Resolved 13 May 2020
Resolution: Fire pump from 2019 had been switched out. New pump tested properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 November 2019
Resolved
Conduct repairs to port rudder and associated steering and propulsion equipment to satisfaction of the USCG. 46 CFR 143.205
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2020
Resolution: Reviewed photos of repairs in shipyard. (Company placed vsl back in water without notifying the CG)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2019
Resolved
Prove proper operation of propulsion system. 46 CFR Part 143
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2020
Resolution: Witnessed proper operation via underway trials.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 November 2019
Resolved
Prove proper operation of the steering system.46 CFR Part 143
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2020
Resolution: Witnessed proper operation via underway trails.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 November 2019
Resolved
Vessel does not have required marking of name and hailing port on hull
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2020
Resolved 13 May 2020
Resolution: Required marking was completed in the dry dock.
Fire Fighting
Issued 2 October 1997
Resolved
46 C.F.R. 25.30-20(b)(1) Does not have the minimum fire extinguishers as required.
Condition: Unknown
Due 15 November 1997
Resolved 9 September 2020
Resolution: Verified minimum fire extinguishers onboard for COI inspection.
Documentation
Issued 2 October 1997
Resolved
33 CFR 155.450 Missing Discharge of Oil Placard.
Condition: Unknown
Due 15 November 1997
Resolved 9 September 2020
Resolution: Verified Discharge of oil placard posted for COI inspection.
Accommodation/Occupational Safety
Issued 2 October 1997
Resolved
33 CFR 151.59 Missing Garbage(MARPOL) Placard.
Condition: Unknown
Due 15 November 1997
Resolved 9 September 2020
Resolution: Verified updated MARPOL placard posted for COI inspection.
Documentation
Issued 2 October 1997
Resolved
46 CFR 15.610 Vessel operator did not have his license available._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 November 1997
Resolved 9 September 2020
Resolution: Master onboard for COI inspection had license available.
Documentation
Issued 2 October 1997
Resolved
46 C.F.R. 67.323 Certificate of Documentation has expired._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 November 1997
Resolved 9 September 2020
Resolution: Valid COD for COI inspection.
Documentation
Issued 2 October 1997
Resolved
46 CFR 80.25 FCC License was not available._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 November 1997
Resolved 9 September 2020
Resolution: FCC License was on board for COI inspection.
Engineering
Issued 2 October 1997
Resolved
COTP Machinery Guards not placed over moving shafts of main engines.
Condition: Unknown
Due 15 November 1997
Resolved 9 September 2020
Resolution: Guards in nplace on new engines during COI inspection.