PETROBRAS 10000

PETROBRAS 10000 is a mobile offshore drilling unit. The Coast Guard has recorded 11 inspections since 2017, most recently in June 2018, along with 7 deficiencies.

Records from 2017 to 2018. Most recent: inspection, 25 June 2018.

Built
Not recorded
Last inspected
25 June 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9404352
1460028
Flag
MARSHALL ISLANDS
Maury page id
psix-1460028

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded8
Years with a record 2 calendar years (2017–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

25 June 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6512645
10 May 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6410942
2 May 2018 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6458547
1 May 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6411373
27 April 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6400579
7 March 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6389056
25 February 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6381546
31 January 2018 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6375517
2 December 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6319210
10 October 2017 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6284742
2 October 2017 Deficiency Check · COC-MODU Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6279819

Deficiency record · 7

14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 2 May 2018 Resolved
No parts list was presented at time of inspection with each tech files since 2009.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2018
Resolution: Vessel provided satisfactory evidence of clearence of defs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 May 2018 Resolved
Lifeboat #2 was found to have an air regulator that was leaking at the manifold.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2018
Resolution: Vessel provided satisfactory evidence of clearence of defs.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 October 2017 Resolved
Multiple instances were evident that the vessels Lock out Tag Out (LOTO) system does not ensure that tags were removed by the person who placed the tag. Additionally, LOTO was being used to place out of service components and equipment for purposes other than repair work. Audit the existing LOTO/installed tags and correct as necessary.
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 7 December 2017
Resolution: Demonstratable evidence provided by Chief Engineer [name withheld]
Lifesaving › Launching Appliances › Davit
Issued 16 October 2017 Resolved
Per 10.18.2 of the 1989 MODU Code, before a unit leaves port and at all times during operations and transit, all life-saving appliances should be in working order and ready for immediate use. The davit sheave for lifeboat #1 was frozen and unable to function safely. Lifeboat #1 shall be placed out of service until all components are made serviceable.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Due 17 November 2017
Resolved 18 October 2017
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 16 October 2017 Resolved
Extended to 7Jan18. RSM. Per 10.18.2 of the 1989 MODU Code, before a unit leaves port and at all times during operation and transit, all life-saving appliances should be in working order ready for immediate use. Multiple air bottles were found leaking (low psi), regulators were improperly set and/or leaking, gas charges for doors were depleted, doors lacked gaskets,
Action required: 705 - Other - as specified
Due 7 January 2018
Resolved 7 January 2018
Resolution: Received email from Master about clearance with documentation.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 16 October 2017 Resolved
Per 14.12.5 of the 1989 MODU Code, each lifeboat should, as far as practicable, be launched with its assigned crew aboard and manuevered in the water at least once every 3 months. Per paragraph 11 of MSC Circular 1486 Annex, supplemental training cannot take the place of launching when favorable weather conditions are provided during the 3 month period. Lifeboats were not launched once every 3 months as required. Provide evidence of launching all lifeboats.
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 7 December 2017
Resolution: Demonstratable evidence provided by Chief Engineer [name withheld]
Fire Fighting › Structural - A Class Divisions › Corridors
Issued 16 October 2017 Resolved
Extended to 7Mar18. RSM. Per 9.1.3 of the 1989 MODU Code, the minimum fire integrity of bulkheads and decks should be as prescribed in tables 9-1 and 9-2. Bulkheads should prevent the passage of flame/smoke and per 3.6.1 shall ensure watertight integrity of enclosed compartments. Multiple marine cable transits and doors were incorrectly installed using unapproved materials and/or lacked original packing that reduced their fire integrity. Survey all marine cable transits, doors, and other components to ensure fire integrity is provided.
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 7 January 2018
Resolution: Received email from master annotating clearance via service report.