Records from 2017 to 2026. Most recent: inspection, 30 March 2026.
Inspection history · 28
30 March 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8333931
12 December 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8283489
13 November 2025
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8267894
16 July 2025
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8187269
21 November 2024
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8037757
14 November 2024
Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8111681
15 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7935440
18 October 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7810676
6 September 2023
COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7775184
20 August 2023
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7772693
9 November 2022
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7584325
23 April 2022
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7437408
3 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7405321
8 December 2021
Deficiency Check · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7364459
31 August 2021
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7301319
27 October 2020
MTSA Verification · Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7084878
6 February 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6904090
30 January 2020
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6901856
29 January 2020
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6899205
22 January 2020
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6893659
14 January 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6888917
3 December 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6866996
2 December 2019
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6865349
19 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6839069
11 January 2019
Plan Review (Other than "T") · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6611857
25 September 2018
MTSA Verification · Initial Certification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6548629
17 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6416588
5 October 2017
COI Inspection · MTSA Verification · Administrative Inspection · Hull Examination · Initial Certification · Construction Oversight · Plan Review (Other than "T") · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6282233
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2025
Resolved
Each ring life buoy on a vessel must:
(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150.
The grablines in way of the port bow and stern ring buoys are wasted. Replace the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2025
Resolved 30 March 2026
Resolution: Replaced ring buoys
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2025
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction.
The rail stanchion on the port quarter main deck is fractured. Make repairs to the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2025
Resolved 30 March 2026
Resolution: Repaired
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 November 2025
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported.
The CO2 bottles for the soda dispensers are not secured. Secure the same.
Action required: 10 - Deficiency Rectified
Resolved 30 March 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2025
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew.
The starboard aft embarkation gate is bent and does not properly latch. Make repairs to the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2025
Resolved 30 March 2026
Resolution: Repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2025
Resolved
Each individual bilge suction must be fitted with a suitable strainer having an open area of not less than three times that of the suction pipe.
The bilge strainer in way of the galley suction is wasted. Replace the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2025
Resolved 30 March 2026
Resolution: Replaced
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 13 November 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
The sink in the forward galley is leaking onto the deck creating a hazardous condition. Make repairs to the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2025
Resolved 12 December 2025
Resolution: POC provided photographic evidence of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
There are two open punch outs in way of the junction box in the life jacket storage compantment. Plug the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2025
Resolved 12 December 2025
Resolution: POC provided photographic evidence of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2021
Resolved
Closet in female head has a cable bunch run that is not supported by metal at least every 24". Support cable run to OCMI satisfaction.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2021
Resolved 11 December 2021
Resolution: Calbe run is now supported by metal at least every 24".
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 December 2021
Resolved
Forward starboard side fire door on main deck will close intermediately. Make repairs to OCMI satisfaction for proper automatic release and latch closes.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 December 2021
Resolution: Repairs were made, door closes and latches automatically to the satisfaction of OCMI.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 December 2021
Resolved
Electrical penetration point in starboard aft WTB inside #2 void is missing fire stop.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2021
Resolved 11 December 2021
Resolution: Fire stop was applied to electrical penetration point in starboard aft WTB inside #2 Void.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 October 2020
Resolved
Vessel has out dated light list, coast pilot, charts with no local notice to mariner documents. Provide updated/current charts/publications.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 October 2020
Resolution: Vessel provide updated charts/publications.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 October 2020
Resolved
Self closing fire door for galley entry does not latch when closing automatically. Prove proper self closing operation of fire door.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 October 2020
Resolution: Fire doors were adjusted and tested in presence of attending Marine Inspectors, SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 October 2020
Resolved
Origional COI was not onboard for inspection and endorsement. Provide original signed and embossed COI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 11 January 2021
Resolution: Hand delivered amended COI to vessel rep at Sunbay Marina.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 October 2020
Resolved
Vessel MOB procedures are missing regulation steps (throwing ring buoy). Provide regulation MOB procedures.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 October 2020
Resolution: Vessel has updated MOB procedures with regulation standards.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 28 October 2020
Resolved
Simple instructions for operation of fixed CO2 are needed at bottle location and pull box location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 31 August 2021
Resolution: Simple instructions have been posted.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 29 January 2020
Resolved
Vessels radar was damaged do to allision with the LaSalle St. Bridge. Vessel may remain in service provided there no visibility restricitons or dense traffic. Master has final determination on vessel getting underway based on weather and traffic. Vessel must remain in the Chicago River.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 6 February 2020
Resolution: Radar dome was replaced and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2019
Resolved
Cable runs in aft most steering compartment are not installed with metal supports at least 24" apart. Do not use plastic zip ties. Install cable runs with metal supports at least every 24" to satisfaction of attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2019
Resolved 14 January 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2019
Resolved
Electrical outlet box located in audio/visual closet is not mounted and has no cover. Mount and cover electrical outlet box to satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2019
Resolved 14 January 2020
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 2 December 2019
Resolved
There are no emergency instructions for fire, flooding, heavy weather, or man overboard posted at operating station. Post emergency instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2019
Resolved 14 January 2020
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 2 December 2019
Resolved
There is no placard posted next to radiotelephone installations with emergency broadcast instruction/information. Post emergency broadcast instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2019
Resolved 14 January 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 December 2019
Resolved
Inspection and testing of smoke and fire detecting system has not been completed annually. Inspect and test system to satisfaction of attending Marine Inspectors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 December 2019
Resolved
Forward peak remote insolation valve for drainage system is not operating properly. Repair/replace or perform maintenance on isolation valve and prove proper operation of remote isolation valve to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 December 2019
Resolved
Crew members drill participation is not recorded or logged for vessel fire, abandon ship, and man overboard drills. Perform/record/log all required training and drills to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2019
Resolved 14 January 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 December 2019
Resolved
STBD side fire protection self-closing door will not close within 10 seconds. Repair/replace door to close not less than5 and not more than 10 seconds.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 December 2019
Resolution: Self-closing door closes in not less than 5 and not more than 10 seconds.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2019
Resolved
Fwd port fire station is missing nut on valve stem not allowing proper operation. Repair/replace nut/valve stem and prove proper operation to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2020
Resolved 14 January 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2018
Resolved
Update Oneline diagram
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2018
Resolved 18 September 2019
Resolution: Rectified deficiency. Recieved pictures of all 4 deficiencies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 September 2018
Resolved
Lable all escape hatches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2018
Resolved 26 March 2019
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 25 September 2018
Resolved
Secure all Galley equipment permanently
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2018
Resolved 26 March 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 September 2018
Resolved
post all documents
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2018
Resolved 26 March 2019