Inspection history · 21
6 July 2023
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7734788
26 October 2020
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7084795
16 March 2020
Internal Structural Exam · Cargo Tank Internal · Drydock Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6928712
7 February 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6906430
23 October 2018
Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6566511
18 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6123951
23 May 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5884508
10 April 2015
Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5100219
31 March 2014
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4826288
17 April 2012
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4282836
3 November 2010
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3884878
20 January 2010
Hull Examination · Cargo Tank Internal · Annual Inspection · COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3666131
20 February 2008
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3150664
8 November 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3095336
14 October 2005
COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2514665
29 March 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2033343
10 December 2003
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1957835
10 December 2002
Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1715396
29 April 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1610525
21 December 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1481095
1 September 2000
Deficiency Check · Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1408599
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 15 April 2015
Resolved
Red flag signifying dangerous cargo is broken. Needs to be re-welded.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2015
Resolved 29 May 2015
Resolution: Received email notification with photos of repaired signage.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 15 April 2015
Resolved
Draft marking need to be re-painted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2015
Resolved 29 May 2015
Resolution: Received email notification with photos of re-painted draft markings.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 15 April 2015
Resolved
Repair electrical cable entering stuffing tube at breaker panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2015
Resolved 29 May 2015
Resolution: Received email notification and photos identifying repaired electrical cable.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 April 2015
Resolved
Cargo pump discharge pressure guage lens was damaged by sunlight and guage was unreadable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2015
Resolved 29 May 2015
Resolution: Received email notification and photos of repaired pressure guage.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 15 April 2015
Resolved
Provide proof of hydrostatic testing of cargo piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2015
Resolved 29 May 2015
Resolution: Received documentation of hydrotesting of cargo piping.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 15 April 2015
Resolved
Provide copy of vessel transfer procedures.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2015
Resolved 29 May 2015
Resolution: Received email notification of proof of vessel transfer procedures.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 15 April 2015
Resolved
Repair diesel fuel leak at swivel joint on hose reel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2015
Resolved 29 May 2015
Resolution: Received email notification and photo of repaired swivel joint at hose reel.
Fire Fighting › Portable CO2 Fire Extinguisher › Marine Type Label
Issued 17 April 2012
Resolved
Provide fire extinguisher test records/tags.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Fire extinguishers were tested and have tags.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 17 April 2012
Resolved
Plug containment around transfer station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Containment around tranfer station had drain plugs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 17 April 2012
Resolved
Provide test records for hoses, piping, gauges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Test records were provided for the piping and transfer hoses dated 5/11/2012.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 17 April 2012
Resolved
Label transfer hoses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Transfer hoses were properly labeled.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 April 2012
Resolved
Provide valid COI for the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 17 May 2012
Resolution: Copy of the COI was provided to the vessel until original amendment could be signed. COI amendment for the vessel was drated and routed for signature.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 20 January 2010
Resolved
Properly replace two 24" fuel hose on transfer system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2010
Resolved 11 March 2010
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 20 January 2010
Resolved
Properly hydro cargo piping system and all transfer hoses. (reel system)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2010
Resolved 12 March 2010
Resolution: Received fax copy of the cargo piping and transfer hose test record.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 20 January 2010
Resolved
Properly adjust port stern wire on winch system.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2010
Resolved 11 March 2010
Deck/Cargo › Mooring/Anchoring › Winch
Issued 20 January 2010
Resolved
Properly replace stbd bow wire on winch system.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2010
Resolved 11 March 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 January 2010
Resolved
Properly service two B-II fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2010
Resolved 11 March 2010
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 20 January 2010
Resolved
All Cargo over fill protection devices were frozen. Barge representative, [name withheld] is to prove proper operation prior to on loading cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2010
Resolved 21 December 2010
Resolution: [name withheld] called and confirmed all overfill devices were unfrozen and working properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 8 November 2007
Resolved
No cargo pressure gage on cargo system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2008
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 November 2007
Resolved
No test records for annual testing of cargo piping system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2007
Electrical › Electric Supply System (service) › Cable
Issued 8 November 2007
Resolved
High voltage cable missing connector on bitter end.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 October 2005
Resolved
Provide proof of annual servicing.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2005
Resolved 17 November 2005
Deck/Cargo › Cargo Transfer (solid)
Issued 10 December 2003
Resolved
Will be replaced prior to next cargo transfer LEGACY COMPONENT DESC: Cargo Pump
Condition: Unknown
Due 11 January 2004
Resolved 8 April 2004
Resolution: New pump was installed, conducted test of fuel transfer pump equipment operating satisfactory.
Documentation › Logs/Records
Issued 10 December 2003
Resolved
Transfer hose hydrostatic test is overdue. LEGACY COMPONENT DESC: Transfer Equipment Test/Inspection Records
Due 11 January 2004
Resolved 27 April 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 December 2003
Resolved
Inspection overdue. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 11 January 2004
Resolved 8 April 2004
Resolution: All onboard fire extinguishers where tested and have an expiration of 1 December 2004.
Electrical › Electrical Distribution System (service)
Issued 10 December 2003
Resolved
Could not inspect electric panel due to missing power source. LEGACY COMPONENT DESC: Panelboard
Due 11 January 2004
Resolved 8 April 2004
Resolution: Power was provided and all electrical equipment was energized and operationaly tested satisfactory.
Electrical › Electrical Distribution System (service)
Issued 10 December 2003
Resolved
Missing deck mat for distribution panel. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Due 11 January 2004
Resolved 27 April 2004
Construction/Loadline › Markings
Issued 10 December 2003
Resolved
Draft marks need to be repainted. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 11 January 2004
Resolved 27 April 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 January 2002
Resolved
Service all Extinguishers on barge. Extinguishers are missing service tags and cannot identify when last service was completed on them. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2002
Resolved 6 May 2002
Deck/Cargo › Mooring/Anchoring
Issued 24 January 2002
Resolved
Replace port bow wire rope loop. Loop is frayed and unsafe. LEGACY COMPONENT DESC: Mooring Line/Hawser
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2002
Resolved 6 May 2002
Documentation › Manuals/Policy Documentation
Issued 24 January 2002
Resolved
Place proper MSDS sheets on barge for cargo carried. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2002
Resolved 6 May 2002
Electrical › Electrical Distribution System (service)
Issued 24 January 2002
Resolved
Replace broken ground fault indicator light cover on electrical distribution panel. LEGACY COMPONENT DESC: Ground Detection
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2002
Resolved 6 May 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 January 2002
Resolved
Transfer hose needs annual hydro testing. Hose was placed in service with no hydro test. LEGACY COMPONENT DESC: Transfer Hose
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2002
Resolved 6 May 2002
Deck/Cargo
Issued 1 September 2000
Resolved
LABEL ALL CARGO HATCHES WITH DANGER KEEP OUT.
Condition: Unknown
Due 20 September 2000
Resolved 2 October 2000
Lifesaving
Issued 1 September 2000
Resolved
INSTALL RED FLAG
Condition: Unknown
Due 20 September 2000
Resolved 2 October 2000
Fire Fighting
Issued 1 September 2000
Resolved
SERVICE ALL FIRE EXTINGUISHERS
Condition: Unknown
Due 20 September 2000
Resolved 2 October 2000
Deck/Cargo
Issued 1 September 2000
Resolved
LABEL INTER TANK TRANSFER CONTROL VALVES.
Condition: Unknown
Due 20 September 2000
Resolved 2 October 2000