Records from 2018 to 2026. Most recent: inspection, 27 May 2026.
Documentation record
Registered dimensions (L × B × D)86.3 ft × 20.7 ft × 7.7 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)86.3 ft × 20.7 ft × 7.7 ft
ITC tonnagegross 76 / net 37
BuilderGRAVOIS BOATS LLC · FRANKLIN, LA, UNITED STATES · built 2018
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWASHINGTON, DC
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 15 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Convention (Subpart B), Gross Ton
61 - Regulatory (Subpart C or D), Gross Ton
37 - Convention (Subpart B), Net Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
27 May 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8383519
27 May 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8145242
10 March 2025
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8236358
21 May 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7916904
6 September 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7786765
14 February 2023
Internal Structural Exam · Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7635834
20 June 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7483225
17 May 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7451946
17 March 2021
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7158316
16 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7013339
11 March 2020
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6925205
11 March 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6925507
30 January 2020
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6904802
22 July 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6758445
18 April 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6668498
30 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6402885
27 April 2018
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6402225
20 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6395792
20 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6396081
14 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6391840
7 April 2018
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 6387417
2 April 2018
Administrative Inspection · DAPI Audit · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6383263
27 February 2018
Construction Oversight · Plan Review "T" Boat · Initial Certification · USCG Audit · Welding Related Inspections Qualification Testing
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6362583
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 March 2021
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline, such as a lazarette. STBD forepeak high water visual indicator non-operational.
46 CFR 182.530(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 29 March 2021
Resolution: New light installed. Video evidence provided of satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 March 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Duct tape was observed within an electrical panel covering a breaker switch, holding it in the "On" position.
46 CFR 183.200(b)
Action required: 10 - Deficiency Rectified
Due 18 March 2021
Resolved 18 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 March 2020
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel's managing representative reported transmission failure on the Starboard MDE while mooring. Vessel was taken out of service. Apprise this office of all repair proposal updates. Satisfactory power trials will be observed by a Marine Inspector prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2020
Resolved 16 July 2020
Resolution: Rebuilt stbd transmission installed. Full power trial conducted at varying RPM's. Test SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 July 2019
Resolved
Vessel required to have onboard ready for immediate use fixed -fire fighting for engine compartment. During operations port engine suffered a casualty in the exhaust that led to automatic discharge of Fixed-fire fighting extinguisher system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2019
Resolved 26 July 2019
Resolution: Witnessed satisfactory sea trials of Starbord engine and test of new fireboy. all sat.
Fire Fighting › Fire Pumps › Pressure
Issued 5 April 2018
Resolved
Starboard fire pump pressure gauge displayed 25 PSI, with two hoses rigged. Prove proper operation of starboard fire pump with a capacity of 60 PSI IAW 46 CFR 181.300(b).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 27 April 2018
Resolution: Witnessed proper operation of starboard fire pump
Documentation › Markings/Placards › Capacity Marking
Issued 22 March 2018
Resolved
The vessel's stability letter designates that not more than 84 people may be on the upper deck. The vessel does not have a placard marking the maximum amount of passengers on the upper deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2018
Resolved 5 April 2018
Resolution: Max passenger placard was posted on top step of ladder leading to upper deck.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 March 2018
Resolved
The vessel must conduct a new to zone inspection upon arriving at SEC Maryland NCR OCMI zone.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2018
Resolved 5 April 2018
Resolution: Conducted NTZ inspection.