Records from 2000 to 2017. Most recent: inspection, 7 June 2017.
Inspection history · 22
7 June 2017
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6170576
28 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6113257
28 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6113269
14 July 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5931669
27 May 2012
Ballast Water Examination · COE-Offshore · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4321849
11 February 2011
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3943806
5 February 2010
Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3676099
5 February 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3676112
26 February 2009
Loadline Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · COC-TVE Annual · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3424166
21 January 2009
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3397453
19 May 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3211351
19 May 2008
ISPS I Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3211590
14 May 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3206650
6 February 2008
Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3141515
1 September 2007
STCW 95 Exam · ISPS II Exam · MARPOL Annex I Examination · COC-TVE Renew · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3042232
4 November 2004
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2234589
3 November 2004
ISPS II Exam · COC-TVE Renew
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2233972
30 November 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 295991
30 November 2001
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 295992
30 November 2001
Tank Vessel Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1077268
6 May 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 277250
6 May 2000
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1049370
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 27 May 2012
Resolved
0799 - For inert gas systems of both the flu gas type and the inert gas type, audible and visual alarms shall be provided to indicate the high gas temperature. IGS high temperature sensor failed to communicate high temperature signal to Inert Gas high temperature trip amplifier at 65 degrees Celsius set point on the inert gas panel in the cargo control room. 74 SOLAS(1997 ConsEd) II-2 Regulation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2012
Resolution: 28 May 2012 received class report of repair.
Deck/Cargo
Issued 30 November 2001
Resolved
Make pump room available for inspection.
Condition: Unknown
Due 30 November 2001
Resolved 3 December 2001
Documentation
Issued 30 November 2001
Resolved
Provide flag acceptance for officers license.
Condition: Unknown
Due 30 December 2001
Resolved 3 December 2001