Records from 2018 to 2025. Most recent: inspection, 12 November 2025.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 46 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDIVERSIFIED MARINE SERVICES LLC · BOURG, LA, UNITED STATES · built 2017
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portMOBILE, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 8
12 November 2025
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8261211
14 November 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824602
3 January 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7118900
31 August 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7090238
19 August 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7037498
8 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6970898
27 March 2019
Initial Certification · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6650619
14 August 2018
Initial Certification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6513584
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 August 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 100% of the vessels that has not obtained a valid COI.
Action required: 705 - Other - as specified
Resolved 17 August 2021
Resolution: See Misle Activity #7090238
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 May 2019
Resolved
Vessels Fall overboard prevention procedures do not specifically address the items listed in 46CFR140.425. Produce Fall overboard prevention procedures in line with the requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared, Vessel added Fall overboard prevention procedures.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 May 2019
Resolved
Vessels navigation assessment are not recorded as described in 46CFR140.635(d). Record navigation assessment considerations per 46CFR140.635(a)1-13.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared, navigation assessment added into TVR.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 7 May 2019
Resolved
Vessel is subject to bridge to bridge requirements per 33CFR26.03(a)3 and unable to provide station logs as described by 47CFR80.409(f)(3). Ensure Radiotelephony record logs entries47CFR80.409(f)(3) paragraphs (e)(1), (3), (5) (6), (7), (10), and (11) of this section.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared, station logs are kept in hard copy
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2019
Resolved
Vessels flammable locker stowage locker does not indicated a adequate level of protection as required by 46CFR142.225. Install new flammable locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared flammable locker stowage, vessel provided another suitable steel container that provides an equivalent level of protection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 May 2019
Resolved
Vessels Fire-detection system is not certified and inspected by a registered professional engineer as described in 46CFR142.330(a)7. Provide letter to CG by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience, that shows compliance with paragraphs (a)(1) through (6) of this section
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared, Produced evidence of letter. See Documents
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2019
Resolved
Vessels flammable locker stowage is not equipped with a 40 B:C portable fire extinguisher must be located near the cabinet as required by 46CFR142.225(d). Install a B-II portable fire extinguisher near the cabinet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared, 40 B:C portable fire extinguisher mounted to locker.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2019
Resolved
Vessels fire pump only produced 10 PSI at the pump discharge gage and does not meet the minimum requirements of a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)) As required by 142.325. Repair the Fire pump to ensure it meets the proper pressure
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared, pump showed 60 PSI.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 7 May 2019
Resolved
Vessel does not have audible and visual alarms auxiliary generator engine low lubricating oil pressure and Low hydraulic steering fluid levels at the operating station as described by 46CFR143.230(a)(3) and (6). Install the proper alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared. Vessel installed alarms.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 May 2019
Resolved
Vessels General alarm can not be heard in the crew berthing on second deck and does not meet the requirements as described by 46CFR143.235b (2). Install a repeater that is capable of notifying persons in the above space
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Cleared, vessel installed general alarm in crew berthing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2019
Resolved
Vessels work vests were not equipped with life jacket lights as described in 46CFR140.430(a). Install life jacket lights on all work vests.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2019
Resolution: Approved work vest lights were installed to all work vest's by the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2019
Resolved
Vessels work vests storage container containing a work vest was not marked “WORK VEST” as described by 46CFR140.430(a). Mark all work vest storage containers
Action required: 10 - Deficiency Rectified
Resolved 7 May 2019
Resolution: Storage container containing work vests was marked “WORK VEST” by the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2019
Resolved
Vessels water light does not have a 3 to 6 feet lanyard with a corrosion-resistant clip as required by 46CFR141.360(b)3. Ensure all lifebuoy floating electric water light are installed as described above.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2019
Resolution: 3 to 6 feet lanyard with a corrosion-resistant clip were installed by the completion of the inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2019
Resolved
Vessel only has one lifebuoy floating electric water light and does not meet the minimum requirement of 2 as required by 46CFR141.360(b)3. Install one additional lifebuoy floating electric water light.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2019
Resolution: Vessel installed one additional lifebuoy floating electric water light by the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 27 March 2019
Resolved
Vessel life float is not fitted with a painter per 46CFR141.325(c). Add a painter to Life Float.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2019
Resolution: Vessel added a painter to Life Float by the completion of the inspection.