MAURY USCG vessel records
← All vessels

SEA DRAGON

SEA DRAGON is a 2017 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2017, most recently in January 2026, along with 9 deficiencies and 1 operational control.

Records from 2017 to 2026. Most recent: inspection, 26 January 2026.

Built
2017
Last inspected
26 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 January 2026
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1470078
Flag
UNITED STATES
Maury page id
psix-1470078

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

26 January 2026 Drydock Exam · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8288379
13 January 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8060929
22 October 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8022962
22 May 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7917346
12 March 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7877651
27 December 2023 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7842749
20 October 2022 Drydock Exam · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7572081
1 March 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7403947
22 February 2021 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7135841
19 February 2020 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6911934
27 February 2019 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6633484
27 November 2017 COI Inspection · Initial Certification · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6311463
25 August 2017 Initial Certification · Construction Oversight · Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6251323

Deficiency record · 9

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2026 Resolved
Replace fuel line and ensure double hose clamps are in place at all fuel line connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2026
Resolved 19 February 2026
Resolution: renewed fuel line.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 January 2026 Resolved
Repace 01 fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2026
Resolved 19 February 2026
Resolution: replaced fire bucket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 January 2026 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter,(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Action required: 705 - Other - as specified
Due 9 February 2026
Resolved 16 April 2026
Resolution: OCMI approved, no longer requiring flares on short route.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 October 2022 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. For a vessel of not more than 30.5 meters (100 feet) in length: ABS Steel Vessel Rules (<61 Meters), with the appropriate conversions from the ABS Aluminum Vessel Rules. welds on the outboard aux engine mount (port and starboard) were cracked at lower transon.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 31 October 2022
Resolution: Vessel repaired weld crack
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2022 Resolved
TO MAINTAIN A VALID CERTIFICATE OF INSPECTION, YOU MUST COMPLETE YOUR ANNUAL INSPECTION WITHIN THE PERIODS SPECIFIED IN 176.500(b)(1) AND YOUR CERTIFICATE OF INSPECTION MUST BE ENDORSED. THE ANNUAL INSPECTION HAS NOT BEEN COMPLETED BY 01MAR2022, WHICH IS THE END OF 3 MONTH WINDOW PERTAINING TO THE ANNIVERSARY DATE ON 01DEC2021. A SATISFACTORY COI INSPECTION WILL BE REQUIRED PRIOR TO CARRYING PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2022
Resolution: Satisfactory annual inspection was completed on 09MAR2022.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 March 2022 Resolved
ALL VESSELS MUST HAVE NAVIGATION LIGHTS THAT ARE IN COMPLIANCE WITH THE APPLICABLE SECTRIONS OF RULES OF THE ROAD. ALL AROUND WHITE LIGHT INOPERABLE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2022
Resolved 20 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 February 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 June 2021
Resolution: Vessel submitted DAPI documents.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 February 2021 Resolved
50c - A vessel must carry a first aid kit approved with required content. Provide Required contents in first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 June 2021
Resolution: Vessel provided proof of replacing the expired medicine on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 March 2019 Resolved
Vessel is required to have a 40-B:C portable extinguisher which is acceptable to the cognizant [name withheld] had significant wear from installed brackets bolts. Replace in kind.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2019
Resolved 12 March 2019
Resolution: New 40-B:C extinguisher installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.