MAURY USCG vessel records
← All vessels

JORDYN PAIGE

JORDYN PAIGE is a 1976 towing vessel. The Coast Guard has recorded 12 inspections since 2005, most recently in February 2026, along with 15 deficiencies and 1 casualty investigation in 2005.

Records from 2005 to 2026. Most recent: inspection, 2 February 2026.

Built
1976
Last inspected
2 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 2 February 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2005–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE6773
147094
Flag
UNITED STATES
Maury page id
psix-147094

Documentation record

Registered dimensions (L × B × D)36.8 ft × 18.0 ft × 5.6 ft
Registered tonnagegross 38 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSABINE RIVER FUEL CO. INC · ORANGE, TX, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBAYTOWN, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

2 February 2026 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8304884
10 November 2025 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8268316
31 October 2024 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8027927
7 November 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7821556
8 August 2022 MTSA Verification · Administrative Inspection · Initial Certification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7528007
1 February 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7134031
6 October 2014 Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5000151
21 February 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3151522
5 February 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3145373
13 December 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2839773
27 January 2005 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2281528
4 January 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2270736

Deficiency record · 15

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2025 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Vessel's shore tie junction box was energized and unable to close and latch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 22 January 2026
Resolution: Received video evidence the shore tie breaker fully closed and latched with the power energized.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 14 November 2025 Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Vessel was missing lagging on the port side main engine exhaust.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 3 January 2026
Resolution: Received picture showing new lagging in place.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 November 2025 Resolved
Each towing vessel must be fitted with a general alarm that: Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station”. Vessel did not have a sign in proximity to their general alarm in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 2 February 2026
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 14 November 2025 Resolved
Employee Assistance Program (EAP) education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew-member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. There was no EAP education program display or service hot-line telephone number onboard the vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 21 January 2026
Resolution: EAP contact list posted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 November 2025 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. There was a missing battery-operated smoke detectors in the galley of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 21 January 2026
Resolution: New smoke detector placed in galley area.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 November 2025 Resolved
Vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and procedures and resources to report crimes, including sexual assault and sexual harassment, including information. There was no SASH Policies or Reporting Procedures posted onboard the vessel. 46 USC 11101
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2025
Resolved 21 January 2026
Resolution: Procedures and contacts posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 November 2024 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. The generator's turbocharger and exhaust piping had no lagging installed. Vessel shall enact permanent repairs to the satisfaction of the Coast Guard. 46 CFR 143.220(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 November 2024 Resolved
The following systems must be equipped with gauges at the machinery location:(1) Main engine lubricating oil pressure and main engine RPM;(2) Main engine cooling water temperature; The machinery space had no gauges for the main propulsion engines. Vessel shall enact permanent repairs to the satisfaction of the Coast Guard. 46 CFR 143.230(c)(1) & (2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 November 2025
Resolution: Witnessed operating required gauges on port upper level in engine room near port entrance.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 11 August 2022 Resolved
Towing vessel must be equipped with fathometer. Fathometer inoperable, prove proper operation. 46 CFR 140.725(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 3 October 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2022 Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. Emergency instructions not posted, post as required. 46 CFR 140.405(C)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 24 October 2022
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 11 August 2022 Resolved
Low hydraulic steering level alarm must be provided Prove proper operation of low steering hydraulic alarm. 46 CFR 143.230(a)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 25 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 August 2022 Resolved
At least one fire axe readily accessible, exterior of vessel. Fire axe not on board, install as required. 46 CFR 142.227
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 24 October 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 August 2022 Resolved
Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station” Provide signage as required by CFR. 46 CFR 143.235 (b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 24 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 August 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Repair the following machinery space items: 1. Install valve handle missing from hydraulic sump piping. 2. Repair hydraulic leak outboard Port main engine. 3. Repair leak in potable water hose. 46 CFR 143.205 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 24 October 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 August 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Provide metallic fuel bowl for fuel filter assembly on STBD main engine. 46 CFR 142.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 3 October 2022

Casualty record · 1

4 January 2005Routine · role: Involved in a Marine Casualty · activity 2270736
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DIAMOND BACK (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.