← All vessels
ALVA RICKMERS
ALVA RICKMERS is a 1998 freight ship. The Coast Guard has recorded 9 inspections since 2002, most recently in January 2011, along with 6 deficiencies and 3 operational controls.
Records from 2002 to 2011. Most recent: inspection, 31 January 2011.
- Built
- 1998
- Last inspected
- 31 January 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9178290 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7ZE9
1472
Flag
BAHAMAS, THE
—
Maury page id
psix-1472
Inspections, by type
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it11481 - Displacement, Ton
30703 - Dead Weight, Ton
26047 - Convention (Subpart B), Gross Ton
10209 - Convention (Subpart B), Net Ton
30703 - Dead Weight, Ton
26047 - Convention (Subpart B), Gross Ton
10209 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
31 January 2011
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3937650
20 December 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3913568
9 June 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2674670
6 June 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2671663
7 February 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2581368
2 February 2006
PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2578306
20 March 2003
Security Inspection
Physical examination · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 1760386
27 July 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1652841
21 June 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1634544
Deficiency record · 6
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 January 2011
Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be self closing. The class A fire door in the steering gear room is not self closing as designed.
cite: SOLAS 97 II-2/ 47.1
code: 0799
action 40(c)
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 January 2011
Resolved
Stairways that penetrate more than one deck shall be protected by self-closing doors at all levels. Stairway decks D, E, and F were not closing as designed
cite: SOLAS 97 II-2/ 46.1
code: 0799
action: 40(a)
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 January 2011
Resolved
Doors required to be self-closing shall not be fitted with hold back hooks unless fitted with remote release type. The oil purifying room fire doors were held back by hold back hooks made of rope.
cite: SOLAS 97 II-2/ 47.2
code: 0799
action: 40(a)
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 January 2011
Resolved
"A" class division doors shall be constructed as to be capable of preventing the passage of smoke and flame. During the inspection it was discovered multiple class "A" doors, eg. ladder well and galley doors air could be felt seeping through and around the doors.
cite: SOLAS 97 II-2/ 3.3.3
code: 0799
action: 40(a)
Engineering › Fuel Oil Service System › Piping
Issued 31 January 2011
Resolved
Vessel shall hydrostatically test each transfer piping system at least 1 1/2 times maximum allowable working pressure annually. Vessel was unable to provide documentation of evidence of testing. Vessel shall not conduct bunker operations in U.S. waters until test completed.
cite: 33CFR 156. 170
code: 9900
action: 15(c)
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 2 February 2006
Resolved
Unable to test emergency fire pump. Vessel conducting repairs on emergency fire pump due to its reduced suction. Pump can only feed on fire house. Vessel conducting repairs while on board. Vessel is required to complete repairs before departure and have class to attest.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.