Records from 2017 to 2026. Most recent: inspection, 22 May 2026.
Inspection history · 22
22 May 2026
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8378564
25 April 2026
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8367805
2 April 2026
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8327317
28 August 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8218263
7 February 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8070192
20 January 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8065626
12 November 2024
Deficiency Check · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8031837
18 April 2024
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7898068
11 April 2024
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7894218
1 March 2024
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7871993
31 July 2023
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7754724
6 March 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7645961
23 January 2023
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7625387
12 September 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7558993
15 July 2021
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7253440
4 December 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7106346
7 February 2020
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6900255
10 January 2020
Deficiency Check · ISPS II Exam · Ballast Water Examination · Administrative Inspection · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6884057
28 February 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6635044
21 December 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6601768
17 November 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6582617
12 October 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6285970
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2026
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed opening in the emergency generator switchboard panel are not fitted with blanking plates, creating and exposed, live electrical hazard. 74SOLAS(04) II-1/40.1.3 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2026
Resolved 22 May 2026
Resolution: Received class report attesting to satisfactory installation of blanking plates.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 November 2024
Resolved
Machiner spaces of Category A shall be adequately ventilated so as to ensure that when machinery is operating at full power in all weather conditions an adequate supply of air is maintained to the spaces for the safety and comfort of personnel and the operation of machinery. PSCO observed 02 portable fans on 02 feed pumps.
74SOLAS(09) Ch.II-1 35
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2024
Resolution: Received satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 November 2024
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed multiple leaks of fuel oil in the fuel oil purifier space and on equipment.
74SOLAS(09) Ch. II-2 4.1.1
Action required: 10 - Deficiency Rectified
Resolved 12 November 2024
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 January 2020
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE POVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED A ONE FOOT LONG BY ONE INCH CRACK IN THE LOCKER CAUSED BY THE ANCHOR FLUKE DURING A STORM.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2020
Resolution: Received Class Survey report indicating repairs were made by grinding and re-welding the crack. The welding seam was visually inspected and NDT Penetrating Test were performed with satisfactory results.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 November 2018
Resolved
04109 - FIRE DRILLS - EVERY CREW MEMBER WITH ASSIGNED DUTIES SHALL BE FAMILIAR WITH THESE DUTIES BEFORE THE VOYAGE BEGINS. THE [name withheld] WAS NOT FAMILIAR WITH THE USE OR PURPOSE OF THE FIRE DAMPERS IN THE GALLEY AND COULD NOT DESCRIBE THE PURPOSE OF THE GALLEY'S FIXED CO2 SYSTEM.
-74 SOLAS (14) CH.III/REG 19.2.1
Action required: 10 - Deficiency Rectified
Due 17 November 2018
Resolved 17 November 2018
Resolution: Corrected during exam after crew training from master.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 November 2018
Resolved
04109 - FIRE DRILLS - EACH FIRE DRIL SHALL INCLUDE: .3 CHECKING OF FIREMAN'S OUTFIT AND OTHER PERSONAL RESCUE EQUIPMENT. CREW DID NOT ADDRESS AN AIR LEAK IN THE FIREFIGHTER'S SCBA DURING THE FIRE DRILL
-74 SOLAS (14) CH.III/REG 19.3.4.2.3.
Action required: 10 - Deficiency Rectified
Due 17 November 2018
Resolved 17 November 2018
Resolution: Crew demonstrated corrective actions after drill debrief and training from the master.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 November 2018
Resolved
04109 - FIRE DRILLS - EACH FIRE DRILL SHALL INCLUDE: .5 CHECKING THE OPERATION OF WATERTIGHT DOORS, FIREDOORS, FIRE DAMPERS AND MAIN INLETS AND OUTLETS OF VENTILATION SYSTEMS IN THE DRILL AREA. THE A-0 DOOR TO THE GALLEY AND GALLEY FIRE DAMPERS WERE LEFT OPEN DURING THE DRILL.
-74 SOLAS (14) CH.III/REG 19.3.4.2.5.
Action required: 10 - Deficiency Rectified
Due 17 November 2018
Resolved 17 November 2018
Resolution: CREW DEMONSTRATED CORRECTIVE ACTIONS AFTER DRILL DEBRIEF AND TRAINING FROM THE MASTER
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 12 October 2017
Resolved
0615, 74 SOLAS (CONS. 2014) III / 20.2, 17c : Before the ship leaves port and all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Steering column mount broke while conducting rudder test. Rescue boat is not in working order nor ready for immediate use.
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 13 October 2017
Resolution: PSCE VERIFIED THE RESCUE BOAT WAS REPAIRED AND WAS IN WORKING ORDER.