MAURY USCG vessel records
← All vessels

STEEL C

STEEL C is a freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in September 2025, along with 12 deficiencies and 3 operational controls.

Records from 2017 to 2025. Most recent: inspection, 29 September 2025.

Built
Not recorded
Last inspected
29 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 September 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9700330
1476698
Flag
LIBERIA
Maury page id
psix-1476698

Documentation record

Tonnage as PSIX records it36203 - Convention (Subpart B), Gross Ton
63118 - Dead Weight, Ton
75086 - Displacement, Ton
21375 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

29 September 2025 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8241012
22 December 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8050094
2 December 2024 Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8041774
19 August 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7538032
12 August 2022 In-Service Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7531692
7 October 2021 PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7326121
14 November 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6576806
23 October 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6293127

Deficiency record · 12

10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 December 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 2 December 2024
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 December 2024 Resolved
09198- SANITARY ACCOMMODATION SHALL COMPLY WITH THE FOLLOWING REQUIRMENTS: COLD FRESH WATER AND HOT FRESH WATER AVALIBLE IN ALL WASH SPACES, SHOWER HOSE WAS BROKEN AND WATER WAS SECURED IN BERTHING OILER (ROOM 307)
Action required: 10 - Deficiency Rectified
Resolved 2 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2021 Resolved
Fire fighting systems and appliances shall be maintained and ready for use. PSCO observes nozzle break off hose during pressure test on port side bridge wing. Observed cracks on nozzles on stbd bridge wing, freefall, and rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2021
Resolved 11 October 2021
Resolution: Deficiency Rectified
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2021 Resolved
Nozzles shall be of approved duel-purpose type (i.e. spray/jet). Replacement nozzles for all four stations were not duel purpose (jet only). No additional duel spares on board.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2021
Resolved 11 October 2021
Resolution: Deficiency Rectified
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 7 October 2021 Resolved
The purpose of this regulation is to prevent ignition of combustible/flammable materials. Ignitability of materials shall be restricted. PSCO observed excessive rags wrapped at base of certrifuge in purifying room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: All the rags and other excess combustible items in purifyer room were removed.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 7 October 2021 Resolved
The design, materials, & construction of all watertight doors shall be to the satisfaction of the administration. PSCO observed light on 3 sides of watertight door when closed on main deck stern escape hatch in aft steering.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: Replaced gasket and confirmed proper seal of watertight door.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 14 November 2018 Resolved
Rings, Lines, and letters shall be painted in contrasting color to the hull and permanently marked. Load line on vessel starboard side worn and unreadible.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2018
Resolution: Class Report Submitted.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 November 2018 Resolved
Before the ship leaves port and at all times during the boyage, all life saving appliances shall be in working order and ready for immediate use. Resue boat inoperable. Crew had to replace spark plugs in engine. Port State Examiner witnessed satisfactory operation prior to end of exam.
Action required: 10 - Deficiency Rectified
Resolved 14 November 2018
Resolution: Crew had to replace spark plugs in engine. Port State Examiner witnessed satisfactory operation prior to end of exam.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 November 2018 Resolved
Posters or signs shall be provided on or in the vacinity of survival craft and shall illustrate the purpose of controls and give relevant instructions. Hydrostatic release operating instructions not relevant ot the equpment on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2018
Resolution: Class Report Submitted.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 23 October 2017 Resolved
1510; SOLAS74(14)V/20.1; 40(a)(c); TO ASSIST IN CASUALTY INVESTIGATIONS, SHIPS, WHEN ENGAGED ON INTERNATIONAL VOYAGES SHALL BE FITTED WITH A VOYAGE DATA RECORDER. VDR DOES NOT RECIEVE DATA FROM ECHO DEPTH SOUNDER AS REQUIRED BY RESOLUTION MSC.163(78)/RESOLUTION A.861(20).
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2017
Resolution: RECEIVED KRS CLASS REPORT STATING VESSEL CONTRACTED LOCAL VDR SERVICE TECHNICIAN TO REPAIR VDR. TECHNICIAN REPLACED THE INOPERATIVE NMEA BUFFER, AND THE VDR NOW RECEIVES THE ECHO SOUNDER INPUTS.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 23 October 2017 Resolved
RESCUE BOATS SHALL BE STOWED: IN A STATE OF CONTINUOUS READINESS FOR LAUNCHING IN NOT MORE THAN 5 MIN. CREW WAS UNFAMILIAR WITH THE RESCUE BOAT LAUNCHING ARRANGEMENTS AND UNABLE TO OPERATE WINCH IN ORDER TO LAUNCH RESCUE BOAT WITHIN ALLOTTED TIME. TRAINING WAS CONDUCTED ON THE SPOT AND CREW WAS ABLE TO MEET TIME REQUIREMENTS. SOLAS74(14)III/14.1 10(C)
Due 23 October 2017
Resolved 23 October 2017
Resolution: CORRECTED ON THE SPOT
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 23 October 2017 Resolved
THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF OIL USED IN PRESSURE LUBRICATION SYSTEMS SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. THE ARRANGEMENTS MADE IN MACHINERY SPACES OF CATEGORY A AND WHENEVER PRACTICABLE IN OTHER MACHINERY SPACES SHALL AT LEAST COMPLY WITH THE PROVISIONS OF ... SOUNDING PIPES MAY BE AUTHORIZED IN MACHINERY SPACES;, HOWEVER THE REQUIREMENTS OF PARAGRAPH 2.2.3.5.1.1 NEED NOT BE APPLIED ON CONDITION THAT THE SOUNDING PIPES ARE FITTED WITH APPROPRIATE MEANS OF CLOSURE.OTHER OIL-LEVEL GUAGUES MAY BE USEED IN PLACE OF SOUNDING PIPES SUBJECT TO THE FOLLOWING CONDITIONS: IN CARGO SHIPS, THE FAILURE OF SUCH GAUGES OR OVERFILLING OF THE TANK SHALL NOT PERMIT RELEASE OF FUEL INTO THE SPACE. THE USE OF CYLINDRICAL GUAGE GLASSES IS PROHIBITED. THE ADMINISTRATION MAY PERMIT THE USE OF OIL-LEVEL GUAGES WITH FLAT GLASSES AND SELF CLOSING VLAVES BETWEEN THE GUAGES AND THE FUEL TANKS. THE VESSEL HAD TIED BACK THE SELF CLOSING VALVES BETWEEN THE GAUGES AND FUEL TANKS. CREW REMOVED SELF CLOSING VALVE HOLD BACKS. SOLAS74(II-2)/4.2.3.1.2
Condition: Placed in Improper Service
Due 23 October 2017
Resolved 23 October 2017
Resolution: CORRECTED ON THE SPOT

Ownership record