MAURY USCG vessel records
← All vessels

BALTIC

BALTIC is a 2017 public freight. The Coast Guard has recorded 6 inspections since 2017, most recently in August 2019, along with 3 deficiencies.

Records from 2017 to 2019. Most recent: inspection, 27 August 2019.

Built
2017
Last inspected
27 August 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 August 2019
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2017–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9763784
1478156
Flag
NETHERLANDS
Maury page id
psix-1478156

Documentation record

Tonnage as PSIX records it887 - Convention (Subpart B), Net Ton
3325 - Dead Weight, Metric Ton
4117 - Displacement, Metric Ton
2957 - Regulatory (Subpart C or D), Gross Ton
2957 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

27 August 2019 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6789043
20 August 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6789025
6 July 2018 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6469691
12 April 2018 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6390339
4 April 2018 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6385034
3 November 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6300020

Deficiency record · 3

Lifesaving › Lifebuoys › Immediately Available
Issued 3 November 2017 Resolved
SOLAS 74(2014 CONS) III/20.2:BEFORE THE SHIP LEAVES PORT, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO OBSERVED RELEASE PIN ON BRIDGE FOR LIFEBUOYS COULD NOT BE RELEASED IMMEDIATELY. (10c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Immediately Available
Issued 3 November 2017 Resolved
SOLAS 74(2014 CONS) III/20.2:BEFORE THE SHIP LEAVES PORT, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO OBSERVED CREW NOT DEMONSTRATE IMMEDIATE USE OF ALL LIFEBUOYS DUE TO FOAM BLOCKS ATTATCHED BETWEEN LIFEBUOY AND HOLDER. (10c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: Corrected on the spot.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 November 2017 Resolved
SOLAS 74(2014 CONS)II-2/14.2.2.1: TESTING FIRE-FIGHTING SYSTEMS SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION. PSCO WAS NOT ABLE TO OBSERVE PROPER TESTING OF SMOKE DETECTION SYSTEMS DUE TO LACK OF TESTING EQUIPMENT. (50ac)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 4 April 2018
Resolution: A class report of intervention was recieved attesting that aerosol test gas was oredered and placed on board.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.