OCEAN STEVNS

OCEAN STEVNS is a 2003 towing vessel. The Coast Guard has recorded 1 inspection in 2025, along with 9 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records in 2025. Most recent: operational control imposed, 29 May 2025.

Built
2003
Last inspected
29 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9224960
1479225
Flag
JAMAICA
Maury page id
psix-1479225

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…past their stated due date3
Years with a record 1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it512 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

29 May 2025 PSC A
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8147274

Deficiency record · 9

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service in which they are intended. PSCO observed a leaking cooling water flange on the vessel’s main engine. 74SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 May 2025
Resolved 4 June 2025
Resolution: Vessel completed part replacement. Class reported no more water leakage from main engine cooling water flange. See "04JUN25-Lloyd's Register Factual Statement"
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 29 May 2025 Resolved
The vessel owner or operator must ensure that they maintain a copy of the VRP…and a copy of the Coast Guard approval letter onboard the vessel. The vessel master or crew cannot produce a copy of the vessel’s approved VRP or its approval letter. 33CFR155.5030(g)(1)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 29 May 2025
Resolved 4 June 2025
Resolution: The vessel provided a USCG-approved VRP. See "04JUN25-Lloyd's Register Factual Statement" and "OCEAN STEVNS NTVRP"
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 May 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue boat engine will not continue to operate for more than a minute after initial start. 74SOLAS (24) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2025
Resolved 4 June 2025
Resolution: Class reported the quick-connect fuel hose was found disconnected and was reconnected. Rescue boat engine now operates normally. See "04JUN25-Lloyd's Register Factual Statement"
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 May 2025 Resolved
Each liferaft… shall be stowed with a float free arrangement complying with the requirements of paragraph 4.1.6 of the Code… If a hydrostatic release unit is used in the float-free arrangement, it shall: if disposable…be marked with a means of determining its date of expiry. Liferafts on the port side of the vessel did not have hydrostatic releases marked. 74SOLAS (24) III/13.4.2 LSA Code IV/4.1.6.3.8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2025
Resolved 4 June 2025
Resolution: Class reported that the two hydrostic release units for the port side liferafts were replaced with markings provided. See "04JUN25-Lloyd's Register Factual Statement"
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 May 2025 No resolution recorded
The following tests and inspections shall be carried out weekly and a report of the inspection shall be entered in the logbook. The vessel master or crew could not produce records of lifesaving equipment weekly inspections. 74SOLAS (24) III/20.6
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 May 2025 No resolution recorded
Maintenance, testing and inspections shall be carried out based on guidelines developed by the Organization…ensuring the reliability of fire-fighting systems. The vessel does not have records for servicing of the firefighting equipment. 74SOLAS (20) II-2/14.2.21
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 May 2025 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. The 01 valve handle is missing on the portside fire hydrant and cannot be opened. 74SOLAS (20) II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 11 June 2025
Resolution: Vessel provided photographs of repairs, see "11JUN25 Fire Hydrant Valve def correction Photo" in documents
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 29 May 2025 Resolved
The date when musters are held, details of abandon ship drills and fire drills, enclosed space entry and rescue drills, drills of other life-saving appliances and on-board training shall be recorded in such logbooks as may be prescribed by the Administration. The vessel master or crew could not produce records of emergency drills held onboard.74SOLAS (24) III/19.5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 11 June 2025
Resolution: Vessel provided record of recently completed drills. See "Record of Abandon Ship/Fire drill for def issued 29MAY25- MISLE ACT #8147274" in documents
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 29 May 2025 No resolution recorded
Every ship of 100 gross tonnage and above…shall carry a garbage management plan which the crew shall follow. The vessel does not have a garbage management plan onboard. MARPOL V/10.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025 — due date passed with no resolution recorded